HYDRAULIC POWER CONTROL
3
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
Proportional Directional Valves series:
PDV74 - PDV114 - PDV315
Contents
CAN - Bus components
Electronic joysticks
PDV ATEX version
Hydraulic remote controls
General 4
General description 5
PDI open centre inlet section function 9
PDI closed centre inlet section function 13
PDI inlet sections code numbers 18
PIU soleinoid LS unloading valves 23
PDW working sections code numbers 25
PDE end sections code numbers 29
PDS ow control spool 33
PDR spool centered set 35
PDS pressure control spool 40
Modules and code numbers 42
Shock and suction valves 47
PDL Electrical LSA/B unloading 49
PDLD Proportional Electrical LSA/B unloading 53
PEAC111 Proportional closed loop spool control input signal 0,5 Udc 54
PEAC112 Proportional closed loop spool control input signal control 0 ÷ 10 V 62
PEAC116 Proportional closed loop spool control input signal control 4 ÷ 20 mA 70
PEAC011 Proportional open loop spool control input signal 0,5 Udc 78
PEAC012 Proportional open loop spool control input signal 0 ÷ 10 V 85
PEAC016 Proportional open loop spool control input signal 4 ÷ 20 mA 92
PEAD1 Proportional open loop spool control input signal PWM and ON-OFF 99
PEAP1 Proportional open loop spool control input signal PWM and ON-OFF 105
Overall dimension drawing 112
Product selection chart 132
Composition form 138
PDV114 Series 141
PDV315 Series 297
HYDRAULIC POWER CONTROL
4
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
General The PDV technology platform, is the latest step in proportional directional
valves con guration.
It takes mobile machine control to next level of performance, reliability, and
feature stringent technical demands, exacting quality standard, and safety
regulations.
Based on load sensing technology, are new breakthrough products with
up-grated hydraulic functions that ful l the ever increasing market
demands for improved machines productivity, safety requirements, energy
e cient and environmental operations.
They provides also a wide choice of control options, and are meant to be
used in hazardous area also, according to Atex 2014/34/UE Directive and
IECEx protocol.
Safety Conformity assessment
FMEA and FMEDA, ( failure modes e ects and diagnostic analysis ), are sy-
stematic analysis technique applied in early phases of a given system deve-
lopment, in order to detect weak points early.
When it comes to more complex products and assemblies involving a combi-
nation of both electrical and hydraulic parts, the need to ensure that adegua-
te surveillance over the design and manufacturing of key parts is paramount,
to be compliance with the on-going series Standards IEC 61508.
Evaluation of the achieved performance level PL and relationship
with SIL
Parts of machinery control systems that are assigned to provide safety fun-
ctions are called safety-related parts of control systems and these can consist
in hydraulic valves with hardware and software, and can either be separate
from the machine control system or an integral part of it.
PDV units, can be requested to be applied as “logic units to ensure safety
functions in accordance with Machine Directive EN 13849 .
For the purpose of this part of Machine Directive, the ability of safety- related
parts to perform a safety function is expressed through the determination of
the performance level.
To make the assessment of the quanti able aspects of the PL easier, this part
of EN 13849 provides a simpli ed method based on the de nition of  ve de-
signated architectures that ful l speci c design criteria and behaviour under
a fault condition.
Therefore, the machine builder or system integrator have full accountability
for making the  nal products selection and assuring that all performance,
safety and warning requirements of the application are being met.
PDV74 Proportional Directional Valve
General description
HYDRAULIC POWER CONTROL
5
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 is a hydraulic proportional directional valve, designed to o ers a wide
range controls options and  exibility.
The PDV74 modular system enables bankable groups to perform many in-
dividual tasks, to meeting and exceeding the changing control needs of the
o -highway machines of today, and well into the future to maximize the e -
ciency, controllability and reliability of vehicles.
PDV74 main features:
Load sensing up-stream pressure compensation
High  ow/low pressure drop capability in a compact size
Integrated pump unloading system
Integrated cut-o pump system
Open/closed centre shifting system
Precise metering capabilities
LSA-LSB electrical unloading
LSA-LSB electrical working pressure remote control
Constant  ow regardless of pressure
Working sections symmetrical  ow
Optional priority inlet for steering or di erent priority functions
Optional dual hydraulic pilot and electrohydraulic control
ATEX and IECEx con guration
CAN-Bus comunication
EMC immunity ensures high safety with regard to electro-magnetic
compatibility
PDV74 Proportional Directional Valve
Technical information
HYDRAULIC POWER CONTROL
6
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
BA
A
B
BA
BA
1
5
3
4
2
High pressure port of PPV piston pump
1
supply the closed centre inlet section of PDV74 proportional valve
2
which in
turn feeds the down-stream working sections.
The PDS spool neutral position
4
unload the LS pump signal to tank, so that the swashplate angle is towards the minimum
displacement and pressure in stand-by setting.
The spool position determines the  ow demands ( speed rotation ) of the two HPM motors
5
.
The PDS main spool compares the pressure drop before and after the spool notches ( di erential pressure ∆p ), and therefore,
the pump  ow remain constant.
If the di erential pressure increase, the pump swashplate is swivelled back towards the minimum displacement, and if the dif-
ferential pressure decrease, the swashplate angle increase towards the max  ow displacement until balance is restored within
the valve.
Actuators load determines the working pressure, and the built-in pressure compensator
3
enable simultaneously function
regardless of di erent working pressure.
PDV74 Proportional Valve - Technical Information - Function
Hydraulic circuit general description
HYDRAULIC POWER CONTROL
7
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional Directional Valve
Example of application with OMFB hydraulic package
1
2
3
4
5
6
7
5
1. PPV90 load sensing piston pump
2. Pump slitter gear box
3. I/O controller PHSI7101008
4. PDV74/6 closed centre inlet
5. Electronic double axis joystick PEJD
6. Graphic display PDHI703000
7. PPM40 piston motor
HYDRAULIC POWER CONTROL
8
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Oil  ow rate
PDI inlet section, P port 160 l/min (max) 42 US gal/min
PDIM - Mid inlet section, P port 250 l/min 66 US gal/min
A, B port with pressure compensator 130 l/min 34 US gal/min
A, B port without pressure compensator 140 l/min 37 US gal/min
Max. pressure
P port
Pressure relief valve setting 400 bar 5800 psi
Working pressure 370 bar 5370 psi
A, B port 370 bar 5370 psi
Ty port, directly to tank
T port
Static 25 bar 363 psi
Dynamic 37 bar 537 psi
Max. pilot pressure oil supply 18 ÷ 22 bar 260 ÷ 320 psi
Oil temperature
Recommended 30 ÷ 65 °C 86 °F ÷ 149 °F
Min -30 °C -22 °F
Max 90 °C 194 °F
Ambient temperature -30 ÷ 60 °C -22 ÷ 140 °F
Oil viscosity
Operating range 12 ÷ 75 mm
2
/sec 65 ÷ 347 SUS
Min 4 mm
2
/sec 39 SUS
Max 460 mm
2
/sec 2128 SUS
Spool stroke
Standard 7 mm 0,28 in
Flow control proportional range 5,5 mm 0,22 in
Pressure control propotional range 7 mm 0,28 in
Daed band spool
Flow control 1,5 mm 0,06 in
Pressure control 1,5 mm 0,06 in
Max internal leakage A/B port
at 100 bar [1450 psi] and 21 mm
2
/sec
A/B T without shock valves 21 cm
3
/min 1,28 in
3
/min
A/B T with shock valves 25 cm
3
/min 1,53 in
3
/min
Filtration Max. contamination: class 9 according to NAS 1638 (20/18/15 according to ISO 4406)
PDV74 internal  lters, mesh 100 m
Mineral oil hydraulic  uid: according to DIN 51524 and 51525 or ISO 6743/4 PDV74 can also be used with phosphate esters
(HFDR), water-glycol (HFC) or water oil (HFB) mixes, subject to our Technical Dept. approval
PDH module - hydraulic control
Pilot pressure
Spool start movement 4 bar / 58 psi
Spool end stroke 15 bar / 218 psi
Max. pilot pressure 30 bar / 436 psi
The hydraulic features listed in this chart, are typical measured data obtained by using mineral based hydraulic oil according
to DIN 51524 with a viscosity of 21 mm
2
/sec [102 SUS] and a temperature of 50 °C [122 °F]
PDV74 Proportional Valve
Technical data
HYDRAULIC POWER CONTROL
9
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
Hydraulic diagram
Tg
Lp
TLsP
Pg
ES
1
2
3
Neutral  ow-pressure drop in PDI, open centre
0
5
10
15
20
25
0 20 40 60 80 100 120 140
l/min
Q
5 10
15 20 25 300
US gal/min
Q
ȴƉ
0
50
100
150
200
300
ȴƉ
250
350
bar
ƉƐŝ
35
0
50
100
150
2
00
250
300
350
0 20 40 60 80 100 120 140
0
1000
2000
3000
ȴƉ
4000
5000
ƉƐŝ
5 10 15 20 25 300
h^ŐĂůͬŵŝŶ
Q
ȴƉ
bar
Q
ůͬŵŝŶ
35
Designed for use with  xed displacement pumps.
Inlet comes standard with pressure compensated 3-way  ow
regulator
1
, that when pump is started and working sections
spools are in neutral position, it’s unloaded to tank, and the oil
ow being supplied from the pump, passes through the 3-way
ow regulator to tank with minimal o -load pressure drop (see
diagram below).
When one or more of the spools are actuated, the highest wor-
king pressure signal is fed to the 3-way  ow regulator, that main-
tains the ∆p at a constant level, so that the  ow rate is indepen-
dent of the load, and proportional to the opened spool area.
The built in pressure reducing valve
2
, act as the pilot pressure
supply for the electrical actuators, as well as, the hydraulic remote
controls.
When the main PDS spools are actuated, the exceeding pump
ow is being sent to tank at the highest load pressure value.
If the working pressure reaches the setting of the upstream max
pressure pilot relief valve
3
, the 3-way  ow regulator will be
opened to tank, thus limiting the working pressure inside the
complete PDV.
On this con guration, the level of safety degrees for the complete
PDV valve is really low, therefore, operator’s great supervision is
strictly request.
PDV74 Proportional Valve - Technical Information - Function
PDI module - Open centre inlet section for  xed displacement
pumps
Pressure relief valve characteristic in PDI,
open centre
HYDRAULIC POWER CONTROL
10
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Hydraulic diagram
Tg
Lp
TLsP
ES
Pg
Neutral  ow-pressure drop in PDI, open centre
0
5
10
15
20
25
0 20 40 60 80 100 120 140
l/min
Q
5 10 15 20 25 300
US gal/min
Q
ȴƉ
0
50
100
150
200
300
ȴƉ
250
350
bar
ƉƐŝ
35
0
50
100
150
2
00
250
300
350
0 20 40 60 80 100 120 140
0
1000
2000
3000
ȴƉ
4000
5000
ƉƐŝ
5 10 15 20 25 300
h^ŐĂůͬŵŝŶ
Q
ȴƉ
bar
Q
ůͬŵŝŶ
35
Designed for use with  xed displacement pumps.
Inlet comes standard with pressure compensated 3-way  ow
regulator
1
, that when pump is started and working sections
spools are in neutral position, it’s unloaded to tank, and the oil
ow being supplied from the pump, passes through the 3-way
ow regulator to tank with minimal o -load pressure drop (see
diagram below).
When one or more of the spools are actuated, the highest wor-
king pressure signal is fed to the 3-way  ow regulator, that main-
tains the ∆p at a constant level, so that the  ow rate is indepen-
dent of the load, and proportional to the opened spool area.
The built in pressure reducing valve
2
, act as the pilot pressure
supply for the electrical actuators, as well as, the hydraulic remote
controls.
When the main PDS spools are actuated, the exceeding pump
ow is being sent to tank at the highest load pressure value.
If the working pressure reaches the setting of the upstream max
pressure pilot relief valve
3
, the 3-way  ow regulator will be
opened to tank, thus limiting the working pressure inside the
complete PDV.
According to an electrical signal coming from the remote controls
or I/O controller, the PDU solenoid unloading valve
4
, enable
the LS signal to be relieved to tank, and the e ect of this con -
guration is an almost pressureless system, where the activated
actuators will be automatically catted o .
The pressure in the system will be reduced to the sum of the tank
port pressure, plus the neutral  ow pressure drop through the
3-way  ow regulator.
Care must be given, because all the actuators whose working
pressure is lower than the pressure drop through the 3-way regu-
lator, might be still operated.
Also with the use of PDU emergency solenoid unloading valve,
the level of safety degrees for the complete PDV valve is quite low,
therefore, operator’s supervision is required.
1
2
3
4
PDV74 Proportional Valve - Technical Information, Function.
PDI module - Open centre inlet section for  xed displacement
pumps, and emergency LS unloading valve (PIU)
Pressure relief valve characteristic in PDI,
open centre
HYDRAULIC POWER CONTROL
11
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
Hydraulic diagram
T
Ls
P
Pg
ES
Lp
Ty
Tg
Neutral  ow-pressure drop in PDI, open centre
0
2
4
6
8
0 20 40 60 80 100 120 140
l/min
bar
Q
ȴƉ
5 10
15 20 25 300
US gal/min
Q
0
30
60
90
ȴƉ
120
ƉƐŝ
35
0
50
100
150
2
00
250
300
350
0 20 40 60 80 100 120 140
0
1000
2000
3000
ȴƉ
4000
5000
ƉƐŝ
5 10 15 20 25 300
h^ŐĂůͬŵŝŶ
Q
ȴƉ
bar
Q
ůͬŵŝŶ
35
Designed for use with  xed displacement pumps.
Inlet comes standard with pressure compensated 3-way  ow
regulator
1
, that when pump is started and working sections
spools are in neutral position, it’s unloaded to tank, and the oil
ow being supplied from the pump, passes through the 3-way
ow regulator to tank with minimal o -load pressure drop (see
diagram below).
When one or more of the spools are actuated, the highest wor-
king pressure signal is fed to the 3-way  ow regulator, that main-
tains the ∆p at a constant level, so that the  ow rate is indepen-
dent of the load, and proportional to the opened spool area.
The built in pressure reducing valve
2
, act as the pilot pressure
supply for the electrical actuators, as well as, the hydraulic remote
controls.
When the main PDS spools are actuated, the exceeding pump
ow is being sent to tank at the highest load pressure value.
If the working pressure reaches the setting of the upstream max
pressure pilot relief valve
3
, the 3-way  ow regulator will be
opened to tank, thus limiting the working pressure inside the
complete PDV.
By means of an electrical signal coming from the remote controls
or I/O controller, the PDU solenoid valve
4
, operates the poppet
type pilot operated valve
5
, which in turn, allows the full  ow co-
ming from the pump to be relieved to tank, bypassing the 3-way
ow regulator
1
.
The e ect of this condition is a complete and safely pressureless
system, where all actuators will be automatically catted-o , and
the pressure into the system will be reduced to the sum of the
tank port pressure, plus the pressure drop through the poppet
unloading valve (see characteristic curve below)
When the inlet section comes with this con guration and the
pump unloading system is connected with the active fault
monitoring spool actuators, the level of safety degree protec-
tion for the complete hydraulic system becomes very high,
operator free, and helps OEM to meet the PL ( Performance
Level ) required to be comply with the safety demands of Ma-
chinery Directive 2006/42/EC.
1
2
3
4
PDV74 Proportional Valve - Technical Information - Function
PDI module - Open centre inlet section for  xed displacement
pumps, and integrated pump unloading system
Pressure relief valve characteristic in PDI,
open centre
5
HYDRAULIC POWER CONTROL
12
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Hydraulic diagram
Tg
Lp
TLsP
ES
Pg
Neutral  ow-pressure drop in PDI, open centre
0
5
10
15
20
25
0 20 40 60 80 100 120 140
l/min
Q
5 10 15 20 25 300
US gal/min
Q
ȴƉ
0
50
100
150
200
300
ȴƉ
250
350
bar
ƉƐŝ
35
0
50
100
150
2
00
250
300
350
0 20 40 60 80 100 120 140
0
1000
2000
3000
ȴƉ
4000
5000
ƉƐŝ
5 10 15 20 25 300
h^ŐĂůͬŵŝŶ
Q
ȴƉ
bar
Q
ůͬŵŝŶ
35
Designed to be con gured either as open centre (  xed displa-
cement pumps ) or closed centre version ( variable displace-
ment pumps)
Inlet comes standard with pressure compensated 3-way  ow
regulator
1
, that when pump is started and working sections
spools are in neutral position, it’s unloaded to tank, and the oil
ow being supplied from the pump, passes through the 3-way
ow regulator to tank with minimal o -load pressure drop (see
diagram below).
When one or more of the spools are actuated, the highest wor-
king pressure signal is fed to the 3-way  ow regulator, that main-
tains the ∆p at a constant level, so that the  ow rate is indepen-
dent of the load, and proportional to the opened spool area.
The built in pressure reducing valve
2
, act as the pilot pressure
supply for the electrical actuators, as well as, the hydraulic remote
controls.
When the main PDS spools are actuated, the exceeding pump
ow is being sent to tank at the highest load pressure value.
If the working pressure reaches the setting of the upstream max
pressure pilot relief valve
3
, the 3-way  ow regulator will be
opened to tank, thus limiting the working pressure inside the
complete PDV.
By acting clockwise on the pilot shifting spool
4
, without chan-
ging any components, the inlet section circuit will be transformed
into closed centre con guration.
In this con guration the load sensing pilot pressure is led to pump
control via the LS connection. When a main spool is actuated,
the pump regulator will adjust the displacement so that the set
di erential pressure ( stand-by pressure ) between P and LS signal
is maintened.
The pressure relief valve 3 is to be set at 35 bar above maximum
cut-o pressure set on the pump.
The LS control performs as a constant pressure control also, decre-
asing pump displacement when system pressure reaches the PC
setting.
The pressure compensating function has the priority over the load
sensing function.
1
2
3
4
PDV74 Proportional Valve - Technical Information - Function
PDI module - Open centre inlet section for  xed displacement pumps,
with pilot shifting spool for closed centre variable displacement pumps
Pressure relief valve characteristic in PDI,
open centre
Patent pending
HYDRAULIC POWER CONTROL
13
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
Hydraulic diagram
TLsP
Tg
Lp
Pg
ES
0
50
100
150
2
00
250
300
350
0 20 40 60 80 100 120 140
0
1000
2000
3000
ȴƉ
4000
5000
ƉƐŝ
5 10 15 20 25 300
h^ŐĂůͬŵŝŶ
Q
ȴƉ
bar
Q
ůͬŵŝŶ
35
Designed for use with LS variable displacement pumps.
Inlet comes standard without pressure compensated 3-way  ow
regulator.
When pump is started and PDV spools are in neutral position, the
LS pump signal is unloaded to tank.
When one or more of the spools are actuated, the highest signal
is sent to the pump regulator that control the pump swashplate
angle.
The PDS main spool compares the pressure drop before and after
the spool notches (di erential pressure ∆p), and therefore, the
pump  ow remain constant.
The position of the PDS spool determines the  ow demand. If the
di erential pressure increase, the pump swashplate is swivelled
back towards the minimum displacement, and if the di erential
pressure decrease, the swashplate angle increase towards the max
ow displacement until balance is restored within the valve.
The inlet section can comes with an optional pressure relief valve
1
that should be set at pressure about 35 bar above maximum
system pressure set on the pump regulator.
According to an electrical signal coming from the remote controls
or I/O controller, the PIU solenoid unloading valve
2
enable the
LS signal to be relieved to tank.
The e ect of this con guration is an almost pressureless system,
where the activated actuators will be automatically catted o ,
and the pressure in the system will be reduced to the sum of the
tank port pressure, plus the di erential pressure of the pump,
therefore, care must be given, because all the actuators whose
working pressure is lower than the remaining pressure might be
still operated.
The built in pressure reducing valve
3
, act as the pilot pressure
supply for the electrical actuators, as well as, the hydraulic remote
controls.
Also with the use of PIU emergency solenoid unloading valve, the
level of safety degrees for the complete PDV valve is quite low,
therefore, operator’s great supervision is required.
1
2
3
PDV74 Proportional Valve - Technical Information - Function
PDI module - Closed centre inlet section for variable LS displacement
pumps, and emergency LS unloading valve (PIU)
Pressure relief valve characteristic in PDI,
open centre
HYDRAULIC POWER CONTROL
14
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Hydraulic diagram
Tg
ES
P1
Pg
PLsT
Lp
Ty
Pressure drop cut-o system in PDI, closed centre
0
2
4
6
8
0 20 40 60 80 100 120 140
l/min
bar
Q
ȴƉ
5 10 15 20 25 300
US gal/min
Q
0
30
60
90
ȴƉ
1
20
ƉƐŝ
35
0
50
100
150
2
00
250
300
350
0 20 40 60 80 100 120 140
0
1000
2000
3000
ȴƉ
4000
5000
ƉƐŝ
5 10 15 20 25 300
h^ŐĂůͬŵŝŶ
Q
ȴƉ
bar
Q
ůͬŵŝŶ
35
Designed for use with LS variable displacement pumps.
This version of inlet comes standard with a double stage cut-o
pump system
1
, that when activated according to an electrical
signal
2
, all down-stream working section will be perfectly and
safely sealed from pressure and  ow, protecting the complete
hydraulic machines control against the negative e ect of the re-
maining stand by pressure.
Inlet comes standard without pressure compensated 3-way  ow
regulator.
When pump is started and PDV spools are in neutral position, the
LS pump signal is unloaded to tank.
When one or more of the spools are actuated, the highest signal
is sent to the pump regulator that control the pump swashplate
angle.
The PDS main spool compares the pressure drop before and after
the spool notches (di erential pressure ∆p), and therefore, the
pump  ow remain constant.
The position of the PDS spool determines the  ow demand. If the
di erential pressure increase, the pump swashplate is swivelled
back towards the minimum displacement, and if the di erential
pressure decrease, the swashplate angle increase towards the max
ow displacement until balance is restored within the valve.
The inlet section can comes with an optional pressure relief valve
3
that should be set at pressure about 35 bar above maximum
system pressure set on the pump regulator.
The built in pressure reducing valve
4
, act as the pilot pressure
supply for the electrical actuators, as well as, the hydraulic remote
controls.
When the inlet section comes with this con guration and the
cut-o pump system is connected with the active fault moni-
toring spool actuators, the level of safety degree protection
for the complete hydraulic system becomes very high, opera-
tor free, and helps OEM to meet the PL ( Performance Level )
required to be comply with the safety demands of Machinery
Directive 2006/42/EC.
12
3
4
PDV74 Proportional Valve - Technical Information - Function
PDI module - Closed centre inlet section for variable LS displacement
pumps and pump cut-o system
Pressure relief valve characteristic in PDI,
closed centre
HYDRAULIC POWER CONTROL
15
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
Hydraulic diagram
Ls
P
T
TTPLs
Lp
TLs TP
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Q
l/min
5 10 15 20 25 300
US gal/min
Q
35
45 50 55 60 65 7040
0
50
100
150
200
250
300
350
ȴƉ
bar
0
1000
2000
3000
ȴƉ
4000
5000
ƉƐŝ
Designed for use with LS variable displacement pumps.
PDIM is a MID inlet section that allows the PDV74 to be supplied
with a larger variable pump  ow capacity with a lower pressure
drop.
PDIM enable to PDW to be mounted on both sides of the pump
side module, therefore, the PDW  tted on PMID left side, the A-B
work port position are reversed.
Inlet comes standard without pressure compensated 3-way  ow
regulator.
When pump is started and PDV spools are in neutral position, the
LS pump signal is unloaded to tank.
When one or more of the spools are actuated, the highest signal
is sent to the pump regulator that control the pump swashplate
angle.
The PDS main spool compares the pressure drop before and after
the spool notches (di erential pressure ∆p), and therefore, the
pump  ow remain constant.
The position of the PDS spool determines the  ow demand. If the
di erential pressure increase, the pump swashplate is swivelled
back towards the minimum displacement, and if the di erential
pressure decrease, the swashplate angle increase towards the max
ow displacement until balance is restored within the valve.
The inlet section may comes with an optional pressure relief valve
that should be set at pressure about 35 bar above maximum
system pressure set on the pump regulator.
According to an electrical signal coming from the remote controls
or I/O controller, the PIU solenoid unloading valve enable the LS
signal to be relieved to tank.
The e ect of this con guration is an almost pressureless system,
where the activated actuators will be automatically catted o ,
and the pressure in the system will be reduced to the sum of the
tank port pressure, plus the di erential pressure of the pump,
therefore, care must be given, because all the actuators whose
working pressure is lower than the remaining pressure might be
still operated.
Also with the use of PIU emergency solenoid unloading valve, the
level of safety degrees for the complete PDV valve is quite low,
therefore, operator’s great supervision is required.
PDV74 Proportional Valve - Technical Information - Function
PDIM module - MID inlet closed centre section for variable LS
displacement pumps, and integrated PIU LS unloading valve
Pressure relief valve characteristic in PDI,
closed centre
HYDRAULIC POWER CONTROL
16
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Tg
Lp
T
Ls
P
PIY
A
B
Ls
LsA
LsB
PIY module
PDV74 Proportional Valve - Technical information
Emergency lowering function
HYDRAULIC POWER CONTROL
17
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional Valve - Technical information
Emergency lowering function
Tg
Lp
T
Ls
P
Pg
ES
A
B
Ls
LsA
LsB
PIY module
This inlet con guration ( for open or closed centre ) is suited to supply the PDV74 with a  ow from an auxiliary manual opera-
ted emergency pump.
Normally the main pump supply the built in pressure reducing valve through the PIY, screw-in cartridge.
In case of main pump failure, the external shuttle valve ensure that the main pressure reducing valve is being supplied from
the emergency hand pump, and the pilot oil supply available for electric actuators.
HYDRAULIC POWER CONTROL
18
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional Valve - Pump side inlet section
PDI modules - open centre version ( xed displacement pumps)
For mechanically actuated valves, only
Code numbers
PDI07A30000 PDI07A30010
BSPP UN-UNF
P, T ports 3/4"
Ls, Pg, Tg ports 1/4"
P, T ports 1 1/16"-12UN-2B
Ls, Pg, Tg ports
7/16"-20UNF-2B
TLsP
Tg
Pg
With pilot oil supply for electrically
and hydraulic actuated valves
Code numbers
PDI07A40000 PDI07A40010
BSPP UN-UNF
Connections threads see page 113
Tg
Lp
TLsP
Pg
ES
3
3
3
With pilot oil supply for electrically
and hydraulic actuated valves
and facility for LS unloading
Code numbers
PDI07A41000 PDI07A41010
BSPP UN-UNF
Connections threads see page 113
Tg
Lp
TLsP
ES
Pg
3
3
4
4
4
3
Product Hydraulic diagram Description
HYDRAULIC POWER CONTROL
19
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
With pilot oil supply, for electrically
and hydraulic actuated valves
and shifting pump system
Code numbers
PDI07B40000 PDI07B40010
BSPP UN-UNF
Connections threads see page 113
Tg
Lp
TLsP
ES
Pg
3
3
With pilot oil supply for electrically and
hydraulic actuated valves , shifting pump
system and facility for LS unloading
Code numbers
PDI07B41000 PDI07B41010
BSPP UN-UNF
Connections threads see page 113
Tg
Lp
TLsP
ES
Pg
3
3
5
3
With pilot oil supply for electrically and
hydraulic actuated valves
3
and pump un-
loading system
4
with external drain line
Code numbers
PDI07A42000 PDI07A42010
BSPP UN-UNF
Connections threads see page 113
T
Ls
P
Pg
ES
Lp
Ty
Tg
4
3
4
3
5
5
6
5
6
5
6
PDV74 Proportional Valve - Pump side inlet section
PDI modules - open centre version ( xed displacement pumps)
3
5
Patent pending
Patent pending
Product Hydraulic diagram Description
HYDRAULIC POWER CONTROL
20
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
With pilot oil supply for electrically and
hydraulic actuated valves
3
and pump un-
loading system
4
with internal drain line
Code numbers
PDI07A45000 PDI07A45010
BSPP UN-UNF
Connections threads see page 113
T
Ls
P
Pg
ES
Lp
Ty
Tg
4
3
4
3
HYDRAULIC POWER CONTROL
21
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
For mechanically actuated valves,
prearranged for pressure relief valve
Code numbers
PDI07C30000 PDI07C30010
BSPP UN-UNF
Connections threads see page 113
TLsP
Tg
Pg
With pilot oil supply for electrically
and hydraulic actuated valves
prearranged for pressure relief valve
Code numbers
PDI07C40000 PDI07C40010
BSPP UN-UNF
Connections threads see page 113
TLsP
Tg
Lp
Pg
ES
3
3
3
With pilot oil supply for electrically and
hydraulic actuated valves preagganged for
LS unloading and pressure relief valve
Code numbers
PDI07C41000 PDI07C41010
BSPP UN-UNF
Connections threads see page 113
3
4
TLsP
Tg
Lp
Pg
ES
3
3
4
4
PDV74 Proportional Valve - Pump side inlet section
PDI modules - closed centre version (variable Ls displacemens pumps)
A1
A1
A1
A1
A1
A1
A
A
A
Product Hydraulic diagram Description
HYDRAULIC POWER CONTROL
22
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 MID inlet with pilot oil supply for
electrically and hydraulic actuated valves,
facility for LS unloading and prearran-
ged for pressure relief valve
Code numbers
PDIM7C41000 PDIM7C41010
BSPP UN-UNF
Connections threads see page 127
4
Ls
P
T
TTP
υLs
Lp
TLs TPϚ
4
4
B3
A1
A3
A1
A1
PDV74 Proportional Valve - Pump side inlet section
PDI modules - closed centre version (variable LS displacement pumps)
Product Hydraulic diagram Description
A2
A1
A2
With pilot pressure oil supply for electri-
cally and hydraulic actuated valves , and
cut-o pump system prearranged for
pressure relief valve
Code numbers
PDI07C44000 PDI07C44010
BSPP UN-UNF
Connections threads see page 113
Tg
Lp
P1
Pg
PLsT
B3
A1
A3
B1
A1
A3
B3
B1
HYDRAULIC POWER CONTROL
23
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional Valve
PIU solenoid LS unloading valves
DIN 43650A Deutsch Parallel Deutsch Perpendicular Junior Power Timer
Normally open
Emergency: push and twist
Normally closed
Emergency: screw
Code numbers
PIU solenoid LS unloading valve codes
Cartridge valve type Connector type 12 Vdc 24 Vdc
Normally closed
Emergency: screw
1
2
DIN 43650A PIU0C023200 PIU0C013200
Deutsch Parallel PIU0C021200 PIU0C011200
Deutsch Perpendicular PIU0C022200 PIU0C012200
Junior Power Timer PIU0C024200 PIU0C014200
Normally open
Emergency: push and twist
1
2
DIN 43650A PIU0A023100 PIU0A013100
Deutsch Parallel PIU0A021100 PIU0A011100
Deutsch Perpendicular PIU0A022100 PIU0A012100
Junior Power Timer PIU0A024100 PIU0A014100
Plug for LS unloading cavity
Plug cavity Hydraulic scheme Code numbers
PIP10000000
HYDRAULIC POWER CONTROL
24
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Max. operating pressure 350 bar
Max. internal leakage
350 bar, 46 mm
2
/sec
1 cm
3
/min
max pressure drop < 1,5 bar
Expected life - 350 bar, 0,5 Hz (1s on / 1s o ) 10.000.000 cycles
Response time for LS pressure relief < 280ms
Oil temperature
Recommended 30 ÷ 60 °C
Min. -30 °C
Max. 90 °C
Ambient temperature -30 ÷ 60 °C
Max. coil surface temperature 160 °C
Oil viscosity
Operating range 10 ÷ 90 cSt
Min. 4 mm
2
/sec
Max. 460 mm
2
/sec
Degree of enclosure
Connector DIN 43650 IP65
Connector Deutsch DT04-2p
IP67
IP69K integrated to coil
Rated voltage 12 Vdc 24 Vdc
Supply voltage 10,6 ÷ 14,6 Vdc 20,4 ÷ 28,6 Vdc
Working temperature -30 ÷ 80 °C
Maximum coil surface temperature 175 °C
Heat insulation Class H (180 °C)
Resistance 7,5 Ω 29,9 Ω
Current consumption 1,6 A 0,8 A
Power consumption 19 W
PDV74 Proportional Valve
PIU solenoid LS unloading valves - Technical data
HYDRAULIC POWER CONTROL
25
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
No facilities for shock-suction valves
Facilities for LS A/B pilot relief valves
Code numbers
PDW71100000 PDW71100010
BSPP UN-UNF
A/B ports 1/2”
Ls-LsA-LsB remote
pressure connections
1/4”
A/B ports 7/8”-14UNF-2B
Ls-LsA-LsB remote
pressure connections
7/16”-20UNF-2B
No facilities for shock-suction valves
No facilities for LS A/B pilot relief valves
Code numbers
PDW71000000 PDW71000010
BSPP UN-UNF
A/B ports 1/2”
Ls-LsA-LsB remote
pressure connections
1/4”
A/B ports 7/8”-14UNF-2B
Ls-LsA-LsB remote
pressure connections
7/16”-20UNF-2B
B
A
TLS T P
LsA
Ls
LsB
Facilities for shock-suction valves
No facilities for LS A/B pilot relief valves
Code numbers
PDW71010000 PDW71010010
BSPP UN-UNF
A/B ports 1/2”
Ls-LsA-LsB remote
pressure connections
1/4”
A/B ports 7/8”-14UNF-2B
Ls-LsA-LsB remote
pressure connections
7/16”-20UNF-2B
B
A
TT
LS P
LsA
Ls
LsB
1
1
1
1
1
2
B
A
TT
LS P
LsA
Ls
LsB
2
2
PDV74 Proportional Valve
PDW modules - working sections with pressure compensator
2
2
Product Hydraulic diagram Description
HYDRAULIC POWER CONTROL
26
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Facilities for shock-suction valves
Facilities for LS A/B pilot relief valves and
electric unloading LS A/B piloting
Code numbers
PDW71111000 PDW71111010
BSPP UN-UNF
A/B ports 1/2”
Ls-LsA-LsB remote
pressure connections
1/4”
A/B ports 7/8”-14UNF-2B
Ls-LsA-LsB remote
pressure connections
7/16”-20UNF-2B
2
Facilities for shock-suction valves
Facilities for LS A/B pilot relief valves
Code numbers
PDW71110000 PDW71110010
BSPP UN-UNF
A/B ports 1/2”
Ls-LsA-LsB remote
pressure connections
1/4”
A/B ports 7/8”-14UNF-2B
Ls-LsA-LsB remote
pressure connections
7/16”-20UNF-2B
1
2
TT
LS P
LsA
Ls
LsB
B
A
1
1
2
2
1
1
2
2
1
B
A
TT
LS P
LsA
Ls
LsB
1
1
2
2
1
1
2
2
PDV74 Proportional Valve
PDW modules - Working sections
with pressure compensator
Product Hydraulic diagram Description
HYDRAULIC POWER CONTROL
27
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
No facilities for shock-suction valves
Code numbers
PDW70000000 PDW70000010
BSPP UN-UNF
A/B ports 1/2”
Ls-LsA-LsB piloting
connections 1/4”
A/B ports
7/8” - 14UNF - 2B
Ls-LsA-LsB piloting
connections
7/16” - 20UNF - 2B
B
A
TLS T P
LsA
Ls
LsB
Facilities for shock-suction valves
Code numbers
PDW70010000 PDW70010010
BSPP UN-UNF
A/B ports 1/2”
Ls-LsA-LsB piloting
connections 1/4”
A/B ports
7/8” - 14UNF - 2B
Ls-LsA-LsB piloting
connections
7/16” - 20UNF - 2B
B
A
TT
LS P
LsA
Ls
LsB
1
1
1
1
1
Functional safety cut-o system
and diverter  ow
Code numbers
PDW75000000 PDW7500010
BSPP UN-UNF
A/B ports 1/2”
Ls-LsA-LsB piloting
connections 1/4”
A/B ports
7/8” - 14UNF - 2B
Ls-LsA-LsB piloting
connections
7/16” - 20UNF - 2B
TT
LS P
PDV74 Proportional Valve
PDW modules - Working sections without pressure compensator
Product Hydraulic diagram Description
HYDRAULIC POWER CONTROL
28
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Facilities for shock-suction valve
With load drop check valve on P channel
Code numbers
PDW73010000 PDW73010010
BSPP UN-UNF
A/B ports 1/2”
Ls-LsA-LsB piloting
connections 1/4”
A/B ports
7/8” - 14UNF - 2B
Ls-LsA-LsB piloting
connections
7/16” - 20UNF - 2B
1
LsA
Ls
LsB
B
A
TT
LS P
1
1
1
1
No facilities for shock-suction valves
With load drop check valve on P channel
Code numbers
PDW73000000 PDW73000010
BSPP UN-UNF
A/B ports 1/2”
Ls-LsA-LsB piloting
connections 1/4”
A/B ports
7/8” - 14UNF - 2B
Ls-LsA-LsB piloting
connections
7/16” - 20UNF - 2B
B
A
TT
LS P
LsA
Ls
LsB
PDV74 Proportional Valve
PDW modules - working sections without pressure compensator
Product Hydraulic diagram Description
HYDRAULIC POWER CONTROL
29
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
No ported, prearranged for
external/internal drain
Code numbers
PDE07010002 PDE07010012
BSPP UN-UNF
Ty ports 1/4” Ty ports 7/16”-20UNF-2B
TLs T PTy
7
7
7
Ls port prearranged for
external/internal drain
Code numbers
PDE07210002 PDE07210012
BSPP UN-UNF
P, T ports 3/4”
Ls, Ty ports 1/4”
P, T ports 1 1/16”-12UN-2B
Ls, Ty ports 7/16”-20UNF-
2B
TP
TTy
7
7
P-T-Ls ports prearranged for
external/internal drain
Code numbers
PDE07110002 PDE07110012
BSPP UN-UNF
Connections thread
see page____
Connections thread
see page____
T
TP
Ty
7
7
7
PDV74 Proportional Valve
PDE modules - End sections
7
A7
A7
A7
A7
A7
A7
Product Hydraulic diagram Description
HYDRAULIC POWER CONTROL
30
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional Valve
PDE modules - MID end sections
MID end section
Code numbers
PDEM7010000 PDEM7010010
BSPP UN-UNF
Ls, Ty ports 1/4”
Ls, Ty ports 7/16”-20UNF-
2B
TLs
TLs Ty
Ty T P
TP
Ty
Product Hydraulic diagram Description
HYDRAULIC POWER CONTROL
31
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional Valve
PDZ module - Dual spool control
PDZ is a small HIC body that can be matched with any
kind of PDV74 working section PDW, to get hydraulic
and electro-hydraulic spool control
A
B
Ls
LsA
LsB
HYDRAULIC POWER CONTROL
32
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional Valve
PDZ module - Dual spool control
PDZ overrall dimensions
For open loop
spool control (Aluminium)
For closed loop
spool control (Cast Iron)
PDZ70000000
1/4” BSPP - 12 mm deep
PDZ71000000
1/4” BSPP - 12 mm deep
PDZ70100000
[⁄ in-20 UNF-2B - 0,47 in deep]
PDZ71100000
[⁄ in-20 UNF-2B - 0,47 in deep]
HYDRAULIC POWER CONTROL
33
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
13
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
10
9
8
3
4
5
6
7
01234567
11
12
13
P B
P A
12345
6
7
10
9
8
3
4
5
6
7
11
12
13
0.04 0.08 0.12 0.16 0.2 0.24 0.280
0.04
0.08
0.12
0.160.20.24
0.28
0
5
10
15
20
25
30
35
Q
A/B
l/min
US gal/min
57911
13
15
7911
1315
73 100 130 160
190
218
100130160190218
0.5 0.55 0.6 0.65
0.7
0.75
0.450.40.35
0.30.25
a (mm)
a (in)
U
S
/U
dc
p (bar)
p (psi)
i (mA)
1
st
8
th
8
th
1
st
1
st
8
th
1
st
8
th
8
th
1
st
1
st
8
th
2012
4
13 14 15 16 17 18 19
56 7891011
400 500 600 700 800 900 1000300
400
500
600
700800900
1000
i (mA)
12Vdc
230 280 330 380 430 480 530180
230
280330380430480
530
i (mA)
24Vdc
PDV74 Proportional Valve
PDS Modules -
Flow control main spool
P
P
LS
LS
TT
Oil ow characteristics
With  ow control spool, the oil  ow depends on type of PDW module ( with or without pressure compensator ) and type of
pump (  xed or variable displacement ).
In the below chart, the ordinate numbers refer to spool size, and the ordinal numbers refer to the same spool size but  tted in
a di erent position with related lost  ow.
HYDRAULIC POWER CONTROL
34
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional Valve
PDS modules - Flow control main spool
Double acting  ow control spool
Size
Max oil  ow
pressure
compensated
l/min
Code numbers and symbol
B
A
T
PT
T
PT
B
A
T
PT
B
A
T
PT
B
A
4-way, 3-position - A, B
closed
4-way, 3-position,
A, B T
4-way, 3-position,
B T; A closed
4-way, 3-position,
A T; B closed
15
PDS00210101 PDS00220102 PDS00280101 PDS00280102
2 7,5
PDS00210102 PDS00220103 PDS00280103 PDS00280104
310
PDS00210103 PDS00220104 PDS00280105 PDS00280106
415
PDS00210105 PDS00220106 PDS00280107 PDS00280108
520
PDS00210106 PDS00220107 PDS00280109 PDS00280110
5,5 25
PDS00210121 PDS00220122 PDS00280111 PDS00280112
630
PDS00210107 PDS00220108 PDS00280113 PDS00280114
740
PDS00210109 PDS00220110 PDS00280115 PDS00280116
850
PDS00210110 PDS00220111 PDS00280117 PDS00280118
960
PDS00210111 PDS00220112 PDS00280119 PDS00280120
10 80
PDS00210113 PDS00220114 PDS00280121 PDS00280122
11 100
PDS00210115 PDS00220116 PDS00280123 PDS00280124
12 115
PDS00210117 PDS00220118 PDS00280125 PDS00280126
13 130
PDS00210119 PDS00220120 PDS00280127 PDS00280128
Double acting asymmetric  ow control spool
Max oil  ow
pressure
compensated
l/min
Code numbers and symbol
B
A
T
PT
T
PT
B
A
T
PT
B
A
T
PT
B
A
AB
4-way, 3-position - A, B
closed
4-way, 3-position,
A, B T
4-way, 3-position,
B
T, A closed
4-way, 3-position,
A T, B closed
15 7,5
PDS00230101 PDS00230102 PDS00270103 PDS00270102
20 40
PDS00230117 PDS00230118 PDS00270119 PDS00270120
25 15
PDS00230123 PDS00230124 PDS00270125 PDS00270126
30 40
- PDS00230116 PDS00270115 PDS00270116
30 50
PDS00230127 - - -
30 60
PDS00230131 - - -
40 20
PDS00230105 PDS00230104 PDS00270101 PDS00270104
40 30
PDS00230115 PDS00230130 PDS00270117 PDS00270118
40 60
PDS00230113 PDS00230114 PDS00270113 PDS00270114
40 110
PDS00230129 - - -
50 30
PDS00230121 PDS00230122 PDS00270123 PDS00270124
60 40
PDS00230125 PDS00230126 - -
65 30
PDS00230107 PDS00230106 PDS00270105 PDS00270106
75 30
PDS00230103 PDS00230112 PDS00270111 PDS00270112
80 40
PDS00230119 PDS00230120 PDS00270121 PDS00270122
110 40
PDS00230109 PDS00230108 PDS00270107 PDS00270108
130 60
PDS00230111 PDS00230110 PDS00270109 PDS00270110
HYDRAULIC POWER CONTROL
35
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional Valve
PDS modules - Flow control main spool
Single acting  ow control spool
Size
Max oil  ow
pressure
compensated
l/min
Symbol and code numbers
B
A
T
PT
B
A
T
PT
3-way, 3-position
P A
3-way, 3-position
P B
1 7,5
PDS00750101 PDS00750102
2 15
PDS00750103 PDS00750104
3 20
PDS00750105 PDS00750106
4 30
PDS00750107 PDS00750108
5 40
PDS00750109 PDS00750110
6 50
PDS00750111 PDS00750112
7 60
PDS00750113 PDS00750114
8 80
PDS00750115 PDS00750116
9 100
PDS00750117 PDS00750118
Double acting  ow control spool,  oating position
Size
Max oil  ow
pressure
compensated
l/min
Symbol and code numbers
B
A
T
PT
B
A
T
PT
3-way, 4-position
oating position on A port
3-way, 4-position
oating position on B port
1 10
PDS00730101 PDS00740101
2 15
PDS00730102 PDS00740102
3 25
PDS00730103 PDS00740103
4 40
PDS00730104 PDS00740104
5 50
PDS00730105 PDS00740105
Spool centered set, code numbers (needed for any kind of  ow control spool)
Tightening torque
Tightening torque
6 Nm
+1
0
6 Nm
+1
0
53,1 lb*in
+8,85
0
53,1 lb*in
+8,85
0
Manual control PDR00300101
Hydraulic - Electrohydraulic PDR00300102
HYDRAULIC POWER CONTROL
36
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional Valve
PDS modules - Flow control main spool
Double acting  ow control, regenerative function
Size
Max oil  ow
pressure
compensated
l/min
Symbol and code numbers
B
A
T
PT
B
A
T
PT
Regenerative circuit on A port Regenerative circuit on B port
1 7,5
215
PDS00610103 PDS00610104
320
PDS00610105 PDS00610106
430
PDS00610107 PDS00610108
540
PDS00610109 PDS00610110
650
PDS00610111 PDS00610112
760
880
PDS00610115 PDS00610116
9 100
10 130
Spool centered set, code numbers (needed for any kind of  ow control spool)
Tightening torque
Tightening torque
6 Nm
+1
0
6 Nm
+1
0
53,1 lb*in
+8,85
0
53,1 lb*in
+8,85
0
Manual control PDR00300101
Hydraulic - Electrohydraulic PDR00300102
HYDRAULIC POWER CONTROL
37
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
13
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
10
9
8
3
4
5
6
7
01234567
11
12
13
P B
P A
12345
6
7
10
9
8
3
4
5
6
7
11
12
13
0.04 0.08 0.12 0.16 0.2 0.24 0.280
0.04
0.08
0.12
0.160.20.24
0.28
0
5
10
15
20
25
30
35
Q
A/B
l/min
US gal/min
57911
13
15
7911
1315
73 100 130 160
190
218
100130160190218
0.5 0.55 0.6 0.65
0.7
0.75
0.450.40.35
0.30.25
a (mm)
a (in)
U
S
/U
dc
p (bar)
p (psi)
150
40
1
st
8
th
8
th
1
st
1
st
8
th
1
st
8
th
8
th
1
st
1
st
8
th
i (mA)
2012
4
13 14 15 16 17 18 19
56 7891011
400 500 600 700 800 900 1000300
400
500
600
700800900
1000
i (mA)
12Vdc
230 280 330 380 430 480 530180
230
280330380430480
530
i (mA)
24Vdc
PDV74 Proportional Valve
PDS modules - Flow control main spool
HYDRAULIC POWER CONTROL
38
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
13
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
10
9
8
3
4
5
6
7
01234567
11
12
13
0.04 0.08 0.12 0.16 0.2 0.24 0.280
0
5
10
15
20
25
30
35
Q
A/B
l/min
US gal/min
57911
13
15
73 100 130 160
190
218
0.5 0.55 0.6 0.65
0.7
0.75
a (mm)
a (in)
U
S/Udc
p (bar)
p (psi)
A (Am)
1
st
8
th
8
th
1
st
1
st
8
th
13
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
10
9
8
3
4
5
6
7
01234567
11
12
13
0.04 0.08 0.12 0.16 0.2 0.24 0.280
0
5
10
15
20
25
30
35
Q
A/B
l/min
US gal/min
57911
13
15
73 100 130 160
190
218
0.5 0.55 0.6 0.65
0.7
0.75
a (mm)
a (in)
U
S/Udc
p (bar)
p (psi)
A (Am)
150
160
40
1
st
8
th
8
th
1
st
1
st
8
th
PDV74 Proportional Valve
Technical characteristics
Oil  ow characteristics PDW without pressure compensator, and pump di erential pressure setting = 16 bar
Oil  ow characteristics PDW without pressure compensator, and pump di erential pressure setting = 25 bar
HYDRAULIC POWER CONTROL
39
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
0
25
50
75
100 125 150 175 200
225
250
275
300
325
350
0
500
1000
1500 2000 2500 3000
3500
4000
4500
5000
0
10
20
30
40
50
60
70
80
90
100
110
120
130
0
5
10
15
20
25
30
35
p (bar)
p (psi)
l/min
US gal/min
Q
A/B
Q
A/B
0
10
20
30
40
50
60
70
80
90
100
110
0
25
50
75
100
125
150
175
200
225
250
275
300
325
350
0
500
1000
1500 2000 2500 3000
3500
4000
4500
5000
p (bar)
p (psi)
l/min
0
5
10
15
20
25
30
US gal/min
Q
A/B
Q
A/B
1
0
10
20
30
40
50
60
0
20
40
60
80
100
120
140
160 180
200
220
1
2
3
4
5
6
7
8
9
10
0
35
5101520
40
25 30
45
50
55
0
150
300
450
600
750
900
Q
A/B
l/min
US gal/min
Q
A/B
bar
psi
ȴƉ
ȴƉ
A/B T
PDV74 Proportional Valve
Technical characteristics
Oil  ow PDW pressure compensated
with LS A/B pilot relief valves
Load independent oil  ow pressure
compensated PDW
PDW pressure drop at max main spool
travel
HYDRAULIC POWER CONTROL
40
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional Valve
PDS modules - Pressure control main spool
P
LS
T
LS
P
T
By using proportional directional valves along with overcenter valves, instability problems may occurs in the form of pressure
surging.
To suite this problems, spools with di erent circuit named “ Pressure Control “ have been developed.
The main purpose of these spools, is to hold in position the 2-way pressure compensator, preventing it from going into unsta-
ble condition, and in turn, to keep the overcenter’s pilot pressure value as stable as possible.
Pressure control spools, must always be used with pressure compensated working sections equipped with pilot LS A/B relief
valves.
Pressure control spool, normally give a higher degree of stability to whole hydraulic system, however, we advise to look after
their use, because:
The valve may loose a bit of pressure compensation, becoming load dependent.
The pump pressure may be considerably higher than that necessary to move the load.
0
5
10
15
20
25
30
0
25 50
75 100 125 150 175 200 225
250
275
300
0
3500
500 1000 1500 2000
4000
2500
3000
0
1
2
3
4
5
6
7
8
ȴƉ
ȴƉ
bar
ƉƐŝ
Q
ůͬŵŝŶ
Q
h^ŐĂůͬŵŝŶ
325
350
4500
5000
0
10
20
30
40
50
60
70
80
90
100
0
25 50
75 100 125 150 175 200 225
250
275
300
0
3500
500 1000 1500 2000
4000
2500
4500
3000
0
2
4
6
8
10
12
14
16
18
20
22
24
26
ȴƉ
ȴƉ
bar
ƉƐŝ
Q
ůͬŵŝŶ
Q
h^ŐĂůͬŵŝŶ
0
10
20
30
40
50
60
70
80
90
100
25 50
75 100 12 5 150 175 200 225
250
275
300
0
3500
500 1000 1500 2000
4000
2500
4500
3000
0
2
4
6
8
10
12
14
16
18
20
22
24
26
ȴƉ
ȴƉ
bar
ƉƐŝ
Q
ůͬŵŝŶ
Q
h^ŐĂůͬŵŝŶ
0
20
180
40
160
60
120
80
140
100
25 50
75 100 125 150 175 200 225
250
275
300
0
3500
500 1000 1500 2000
4000
2500
4500
3000
0
5
10
15
25
30
35
20
40
45
ȴƉ
ȴƉ
bar
ƉƐŝ
Q
ůͬŵŝŶ
Q
h^ŐĂůͬŵŝŶ
HYDRAULIC POWER CONTROL
41
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional Valve
PDS modules - Pressure control main spool
Pressure control spool
Size
Symbol and code numbers
(PC = Pressure control - FC = Flow control)
B
A
T
PT
B
A
T
PT
B
A
T
PT
B
A
T
PT
B
A
T
PT
B
A
T
PT
4-way, 3-position,
A, B closed
4-way, 3-position,
A, B throttled open to T
4-way, 3-position,
A, B closed
4-way, 3-position,
A, B closed
4-way, 3-position,
A throttled open to T,
B closed
4-way, 3-position,
A closed,
B throttled open to T
1
PDS00710113
PCA + B
PDS00720114
PCA + B
PDS00760113
PCA
FCB, Q=--l/min
PDS00770114
PCB
FCA, Q=--l/min
PDS00780113
PCA
FCB, Q=--l/min
PDS00790114
PCB
FCA, Q=--l/min
-
-
PDS00760121
PCA
FCB, Q=--l/min
---
2
PDS00710115
PCA + B
PDS00720116
PCA + B
PDS00760115
PCA
FCB, Q=--l/min
PDS00770116
PCB
FCA, Q=--l/min
PDS00780115
PCA
FCB, Q=--l/min
PDS00790116
PCB
FCA, Q=--l/min
3
PDS00710117
PCA + B
PDS00720118
PCA + B
PDS00760117
PCA
FCB, Q=--l/min
PDS00770118
PCB
FCA, Q=--l/min
PDS00780117
PCA
FCB, Q=--l/min
PDS00790118
PCB
FCA, Q=--l/min
3,5
PDS00710111
PCA + B
PDS00720112
PCA + B
PDS00760111
PCA
FCB, Q=--l/min
PDS00770112
PCB
FCA, Q=--l/min
PDS00780111
PCA
FCB, Q=--l/min
PDS00790112
PCB
FCA, Q=--l/min
4
PDS00710119
PCA + B
PDS00720120
PCA + B
PDS00760119
PCA
FCB, Q=--l/min
PDS00770120
PCB
FCA, Q=--l/min
PDS00780119
PCA
FCB, Q=--l/min
PDS00790120
PCB
FCA, Q=--l/min
Spool centered set, code numbers (needed for any kind of  ow control spool)
Tightening torque
Tightening torque
6 Nm
+1
0
6 Nm
+1
0
53,1 lb*in
+8,85
0
53,1 lb*in
+8,85
0
Manual control PDR00300101
Hydraulic - Electrohydraulic PDR00300102
HYDRAULIC POWER CONTROL
42
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Product Description Aluminium Cast iron
PDM
Mechanical actuation
With lever
PDM10101000 PDM11101000
Without lever
PDM101000000 PDM11100000
PDM
Mechanical actuation,
with  ow adjustment nuts
protection
With lever
PDM10201000 PDM11201000
Without lever
PDM10200000 PDM11200000
PDM
Mechanical actuaƟ on with
direcƟ onal sensors for electri-
cal monitoring of spool valve
movement
Brown
Black
Blue
Vcc +
Gnd -
RL
Vcc 10 V ... 30 V
I < 200 mA
With lever
Normally closed:
PDM11111000
Normally open: PDM11121000
PDF
Friction detent
(for mechanical
actuation only)
Cast iron only
PDF10000001
Flow adjustment protecƟ on
nuts for PDM mechanical
control
PDV74 Proportional Valve
Modules and code numbers
HYDRAULIC POWER CONTROL
43
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
Product Description Aluminium Cast iron
PDC
Rear cover for mechanical
actuation
PDC00000000 PDC10000000
PDH
Hydraulic actuation
A/B pilot port
1/4 BSPP
deep: 12 mm (0,47 in)
PDH70000000
A/B pilot port
1/4 BSPP
deep: 12 mm (0,47 in)
PDH71000000
A/B pilot port
7/16-20UNF-2B
deep: 12 mm (0,47 in)
PDH70000100
A/B pilot port
7/16-20UNF-2B
deep: 12 mm (0,47 in)
PDH71000100
Pilot LS A/B relief valve
50 ÷ 80 bar
PLS0A100000
81 ÷ 380 bar
PLS0A400000
Plug for pilot LS A/B relief valve
cavity
PLS0P000000
PDV74 Proportional Valve
Modules and code numbers
HYDRAULIC POWER CONTROL
44
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Product Description Cast iron only
PDD
Mechanical spool lock device,
manual release
PA - lock PB - free
PDD70100000
PA - free PB - lock
PDD70010000
P
A - lock PB - lock
PDD70110000
PA -  oat PB - free
PDD70200000
P
A - free PB -  oat
PDD70020000
PDV74 Proportional Valve
Modules and code numbers - Detent
HYDRAULIC POWER CONTROL
45
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
Product Description Code numbers
PIZ
For PDI with internal pilot oil
supply
PIZ10000000
PIY
For PDI with external pilot oil
supply
A/B pilot port
1/4 BSPP
deep: 12 mm (0,47 in)
PIY10000000
A/B pilot port
7/16-20UNF-2B
deep: 12 mm (0,47 in)
PIY10000010
For PDE with external drain
line electrical actuation
A/B pilot port
1/4 BSPP
deep: 12 mm (0,47 in)
PED10000000
A/B pilot port
7/16-20UNF-2B
deep: 12 mm (0,47 in)
PED10000010
For PDE with internal drain
line electrical actuation
PEI10000000
For PDE with LS carry-over
A/B pilot port
1/4 BSPP
deep: 12 mm (0,47 in)
PED20000000
A/B pilot port
7/16-20UNF-2B
deep: 12 mm (0,47 in)
PED20000010
For PDE prearranged LS
carry-over
PEI10000000
PDV74 Proportional Valve
Modules and code numbers
HYDRAULIC POWER CONTROL
46
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional Valve
Technical features
PWS-PWA
PWR
PWS, PWA and PWB are shock suction valves design
to absorb shock e ects only, and they should never
be used as a pressure relief valves.
PWS, PWA and PWB are set at an oil  ow of 10 l/min.
If the hydraulic actuator requires a pressure relief
valve function, a PDW module with built-in LS A/B pilot
pressure limit valves should be used
PWR suction valve
HYDRAULIC POWER CONTROL
47
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PWS shock and suction valve for A/B port. Not adjustable
B
A
TT
LS P
LsA
Ls
LsB
Seƫ ng
Pressure
(bar)
Code numbers
50
PWS7M180050
70
PWS7M180070
90
PWS7M180090
110
PWS7M180110
130
PWS7M180130
150
PWS7M180150
180
PWS7M180180
200
PWS7M180200
230
PWS7M180230
260
PWS7M180260
290
PWS7M180290
320
PWS7M180320
350
PWS7M180350
380
PWS7M180380
PWA shock and suction valve for A/B port. Adjustable
B
A
TT
LS P
LsA
Ls
LsB
Range seƫ ng
(bar)
Code numbers
20 ÷ 70
PWA7M180N00
71 ÷ 130
PWA7M180B00
131 ÷ 210
PWA7M180G00
211 ÷ 280
PWA7M180V00
281 ÷ 350
PWA7M180W00
351 ÷ 420
PWA7M180R00
PWB shock valve for A/B port. Not adjustable
B
A
TT
LS P
LsA
Ls
LsB
Seƫ ng
pressure(bar)
Code numbers
50
PWB7M180050
70
PWB7M180070
90
PWB7M180090
110
PWB7M180110
130
PWB7M180130
150
PWB7M180150
180
PWB7M180180
200
PWB7M180200
230
PWB7M180230
260
PWB7M180260
290
PWB7M180290
320
PWB7M180320
350
PWB7M180350
380
PWB7M180380
PDV74 Proportional Valve
Shock and suction valves
HYDRAULIC POWER CONTROL
48
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PWR suction valve for A/B port
Product Hydraulic diagram Code numbers
PWR7M180000
Plug for PWS - PWA - PWB and PWR cavity
Product Hydraulic diagram Code numbers
PWP7M180000
PDV74 Proportional Valve
Modules and code numbers
HYDRAULIC POWER CONTROL
49
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional Valve
PDL module - Electrical LSA/B unloading
ON-OFF actuation normally closed
47
66
248
When PDL is energized, the piloting signal is lead
to tank and in turn the work port oil  ow will be
cutted o .
PDL modules is always to be matched with PDW
pressure compesated.
PDL code numbers
Hydraulic diagram Connector type 12V dc 24V dc
AcƟ ve on LsA
LsA
LsA
LsTLsB
Deutsch Parallel PDL12C11200 PDL12C31200
Deutsch Perpendicular PDL12C12200 PDL12C32200
DIN PDL12C13200 PDL12C33200
JPT PDL12C14200 PDL12C34200
AcƟ ve on LsB
LsA
LsB
LsTLsB
Deutsch Parallel PDL13C11200 PDL13C31200
Deutsch Perpendicular PDL13C12200 PDL13C32200
DIN PDL13C13200 PDL13C33200
JPT PDL13C14200 PDL13C34200
AcƟ ve on LsA and LsB
LsA
LsA
LsTLsB
LsB
Deutsch Parallel PDL11C11200 PDL11C31200
Deutsch Perpendicular PDL11C12200 PDL11C32200
DIN PDL11C13200 PDL11C33200
JPT PDL11C14200 PDL11C34200
AcƟ ve on Ls
LsA
Ls
LsTLsB
Deutsch Parallel PDL14C11200 PDL14C31200
Deutsch Perpendicular PDL14C12200 PDL14C32200
DIN PDL14C13200 PDL14C33200
JPT PDL14C14200 PDL14C34200
HYDRAULIC POWER CONTROL
50
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional Valve
PDL module
PDL code numbers
Hydraulic diagram Connector type 12V dc 24V dc
AcƟ ve on LsA
LsALsTLsB
Deutsch Parallel PDL32C11200 PDL32C31200
Deutsch Perpendicular PDL32C12200 PDL32C32200
DIN PDL32C13200 PDL32C33200
JPT PDL32C14200 PDL32C34200
AcƟ ve on LsB
LsALsTLsB
Deutsch Parallel PDL33C11200 PDL33C31200
Deutsch Perpendicular PDL33C12200 PDL33C32200
DIN PDL33C13200 PDL33C33200
JPT PDL33C14200 PDL33C34200
AcƟ ve on LsA and LsB
LsALsTLsB
Deutsch Parallel PDL35C11200 PDL35C31200
Deutsch Perpendicular PDL35C12200 PDL35C32200
DIN PDL35C13200 PDL35C33200
JPT PDL35C14200 PDL35C34200
AcƟ ve on Ls
LsALsTLsB
Deutsch Parallel PDL34C11200 PDL34C31200
Deutsch Perpendicular PDL34C12200 PDL34C32200
DIN PDL34C13200 PDL34C33200
JPT PDL34C14200 PDL34C34200
HYDRAULIC POWER CONTROL
51
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDL code numbers
Hydraulic diagram Connector type 12V dc 24V dc
AcƟ ve on LsA
LsALsTLsB
Deutsch Parallel PDL32A11100 PDL32A31100
Deutsch Perpendicular PDL32A12100 PDL32A32100
DIN PDL32A13100 PDL32A33100
JPT PDL32A14100 PDL32A34100
AcƟ ve on LsB
LsALsTLsB
Deutsch Parallel PDL33A11100 PDL33A31100
Deutsch Perpendicular PDL33A12100 PDL33A32100
DIN PDL33A13100 PDL33A33100
JPT PDL33A14100 PDL33A34100
AcƟ ve on LsA and LsB
LsALsTLsB
Deutsch Parallel PDL35A11100 PDL35A31100
Deutsch Perpendicular PDL35A12100 PDL35A32100
DIN PDL35A13100 PDL35A33100
JPT PDL35A14100 PDL35A34100
AcƟ ve on Ls
LsALsTLsB
Deutsch Parallel PDL34A11100 PDL34A31100
Deutsch Perpendicular PDL34A12100 PDL34A32100
DIN PDL34A13100 PDL34A33100
JPT PDL34A14100 PDL34A34100
When PDL is deenergized, the piloting signal is
lead to tank and in turn the work port oil  ow will
be cutted o .
PDL modules is always to be matched with PDW
pressure compesated.
47
66
248
PDV74 Proportional Valve
PDL module - Electrical LSA/B unloading
ON-OFF actuation normally open
HYDRAULIC POWER CONTROL
52
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional Valve
PDL module
PDL code numbers
Hydraulic diagram Connector type 12V dc 24V dc
AcƟ ve on LsA
LsA
LsA
LsTLsB
Deutsch Parallel PDL12A11100 PDL12A31100
Deutsch Perpendicular PDL12A12100 PDL12A32100
DIN PDL12A13100 PDL12A33100
JPT PDL12A14100 PDL12A34100
AcƟ ve on LsB
LsA
LsB
LsTLsB
Deutsch Parallel PDL13A11100 PDL13A31100
Deutsch Perpendicular PDL13A12100 PDL13A32100
DIN PDL13A13100 PDL13A33100
JPT PDL13A14100 PDL13A34100
AcƟ ve on LsA and LsB
LsA
LsA
LsTLsB
LsB
Deutsch Parallel PDL11A11100 PDL11A31100
Deutsch Perpendicular PDL11A12100 PDL11A32100
DIN PDL11A13100 PDL11A33100
JPT PDL11A14100 PDL11A34100
AcƟ ve on Ls
LsA
Ls
LsTLsB
Deutsch Parallel PDL14A11100 PDL14A31100
Deutsch Perpendicular PDL14A12100 PDL14A32100
DIN PDL14A13100 PDL14A33100
JPT PDL14A14100 PDL14A34100
HYDRAULIC POWER CONTROL
53
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDLD code numbers
Hydraulic diagram Connector type 12V dc 24V dc
AcƟ ve on LsA
LsA
LsA
LsTLsB
Deutsch Parallel PDL12D11000 PDL12D31000
AcƟ ve on LsB
LsA
LsB
LsTLsB
Deutsch Parallel PDL13D11000 PDL13D31000
AcƟ ve on LsA and LsB
LsA
LsA
LsTLsB
LsB
Deutsch Parallel PDL11D11000 PDL11D31000
AcƟ ve on Ls
Deutsch Parallel PDL14D11000 PDL14D31000
PDV74 Proportional Valve
PDLD module - Electrical LSA/B unloading
Proportional actuation normally open (current signal mA)
PDLD is an electro-hydraulic device that allows
the A/B port working pressure to be remotely an
proportionally operated according to a current
signal (mA). When the working pressure exceed
the setting pressure value, the A/B port oil  ow
will be cutted o .
When PDLD is not energized, PDW is almost pres-
sureless, as well as the A-B oil  ow is cutted o .
47
66
248
HYDRAULIC POWER CONTROL
54
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Pb
T
Pp
Pa
T
Pp
PID
μP
PEAC111 is a proportional high performance PDV spool actuation
with integrated electronics and inductive transducer ( LVDT ) that
operates safely and precisely the main spool movement according
to an electrical signal coming from a remote control.
The input signal by means of the PCB and the two proportional
pressure reducing valves, determines the level of the pilot pressu-
re which moves the main spool.
The spool position is detected in the LVDT transducer which gene-
rates an electric feed-back signal registered by the electronics.
The variation between the input signal and the feed-back signal,
actuates the solenoid valves accordingly, so that, the hydraulic
pilot pressure will drive the main spool in the right position.
All PEAC111 modules comes with integrated fault monitoring
system, available in two version:
Active version
Passive version
Active fault monitoring
When an error state is detected, the two proportional solenoid
valves will be automatically deactivated, a red lamp will light-up
and drive the spool in neutral position (if it’s not seized up ).
The system will only react to failures of more than 500 ms ( in
other words there is delay of half a second before anything
happens ). An alarm signal is sent out through the connector, and
minus is opened.
This error state is memorized, and continues until the system is
being reset by switching o the supply voltage.
Shortly, when the active fault monitoring system is connected
and an error state is detected, the system ensures a fast and
operator free reaction, that will put the complete hydraulic circuit
into venting conditions, thus preventing uncontrollable machine
movements.
Passive fault monitoring
When an error state is detected, the two proportional solenoid
valves will not be deactivated, a red lamp will light-up, but still
control the main spool.
When a fault condition occurs, after a delay of 250 ms an alarm
signal is sent out through a devoted pin
This state is not memorized, and when the faulty state disappears,
the alarm signal will turn to passive again.
In order to prevent the electronic from going into an unde ned
state, any time the system is being triggered or reset, a general
check of power supply and the internal clock frequency is made.
The use of PEAC111 module both passive or active version, allows
the machines hydraulic system to be made with di erent level of
safety degree that for the choice of which it is essential to know
the exactly required functions.
When the PEAC111 module active version is connected with
the pump unloading system, the level of safety degree pro-
tection for the complete hydraulic system becomes very high,
operator free, and helps OEM to meet the PL ( Performance
Level ) required to be comply with the safety demands of Ma-
chinery Directive 2006/42/EC.
PDV74 - PEAC111 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal control 0,5 Udc
HYDRAULIC POWER CONTROL
55
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PEAC111 is de ned by:
Inductive transducer with resolution < 12 µm
Integrated diagnosis and error memory
Fault monitoring transistor output for signal source
Higher spool control accuracy
EMC performace according to Directive 2014/30/UE
Low hysteresis
Quicker reaction time
Spool direction movement output
Integrated PWM/Pulse Width Modulation
Low electrical power
PDV74 - PEAC111 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal control 0,5 Udc
PEAC111 Technical data
Rated supply voltage 10 ÷ 30 Vdc
Max ripple 5%
Signal control 0,5 Udc
Range control signal 0,25 Udc to 0,75 Udc
Neutral spool position 0,5 Udc
Max threshold signal, A port 1 V
Max threshold signal, B port 1 V
Max current signal @ rated voltage 48 mA
Input capacitor 100 ηF
Signal control impedance 25 k
Power consumption 8,7 W
Heat insulation Class H (180°C)
Duty cycle ED 100%
Max current consumption 650 mA
Current consumption in neutral position 80 mA
Coil impedance @ 20°C 8,9 
Dither frequency 50-200 Hz
Recommended frequency 100 Hz
Enclouser degree (Electrical wiring excepted) IP 66 - IP 67 - IP 69K
Weight cast iron body 1,8 kg
Weight aluminium body 1,3 kg
Bootloader function, debugging parameters and set-up function available only
with Deutsch connector DT06-6S
Fault monitoring system
Max current on safety output (pin 5) 50 mA
Reaction time a fault 500 ms
Max current output signal for spool direction moviment 50 mA
Reaction time (constant voltage)
From neutral position to max spool travel 110 - 140 ms
From max spool travel to neutral 70 - 90 ms
Reaction time (neutral switch)
From neutral position to max spool travel 130 - 170 ms
From max spool travel to neutral 70 - 90 ms
HYDRAULIC POWER CONTROL
56
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
47
47,5
96.5
100,5
137,5
100,5
96.5
131.5
47
47,5
Deutsch connector DT06-6S
Enclousure degree IP 69K
PIN-assignment
2
3
6
5
1
4
1 Power supply
2 Input signal control
3 CAN-high
A port-spool
movement signal
4 CAN-low
B port-spool
movement signal
5 Fault monitoring signal
6 Ground
Connector version
Code numbers
Active version Passive version
Cast-iron body Aluminium body Cast-iron body Aluminium body
Deutsch DT06-6S PEAC0121000 PEAC1121000 PEAC0111000 PEAC1111000
DIN 43650 PEAC0121200 PEAC1121200 PEAC0111200 PEAC1111200
Hirschmann connector DIN 43650
Enclousure degree IP 65
PIN-assignment
1
2
3
4
1 Power supply
2 Input signal control
3 Fault monitoring signal
4 Ground
PDV74 - PEAC111 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal 0,5 Udc - Electrical connectors
HYDRAULIC POWER CONTROL
57
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC111 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal control 0,5 Udc
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
1
5
2
3
4
B
A
1
5
2
3
4
T
Ls P
Pg
Tg
Lp
Es
Ty
U+
SC
U-A
B
3B1A2
U+
SC
U-A
B
3B1A2
HYDRAULIC POWER CONTROL
58
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC111 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal control 0,5 Udc
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+
SC
U-A
B
3B1A2
U+
SC
U-A
B
3B1A2
HYDRAULIC POWER CONTROL
59
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC111 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Electrical block diagram for intelligent ring machine control
HMI / Joystick
Main power supply
Battery
Emergency stop or
Man present Switch
System
sensors
Hydraulic venting
MAIN CONTROLLER
Power Supply
System Logic
IN
LOGIC
OUT
Feedback
INPUT
Power Supply
Fault monitoring
PVE fault output
Electronic
circuit logic
MAIN CONTROL VALVE
Fault
detection
HYDRAULIC POWER CONTROL
60
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC111 Electro-hydraulic proportional actuation
Electrical wiring diagram with OMFB I/O controller
Input signal 0,5 Udc
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
61
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC111 Electro-hydraulic proportional actuation
Electrical wiring diagram with OMFB I/O controller
Input signal 0,5 Udc
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
62
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Pb
T
Pp
Pa
T
Pp
PID
μP
PEAC112 is a proportional high performance PDV spool actuation
with integrated electronics and inductive transducer ( LVDT ) that
operates safely and precisely the main spool movement according
to an electrical signal coming from a remote control.
The input signal by means of the PCB and the two proportional
pressure reducing valves, determines the level of the pilot pressu-
re which moves the main spool.
The spool position is detected in the LVDT transducer which gene-
rates an electric feed-back signal registered by the electronics.
The variation between the input signal and the feed-back signal,
actuates the solenoid valves accordingly, so that, the hydraulic
pilot pressure will drive the main spool in the right position.
All PEAC112 modules comes with integrated fault monitoring
system, available in two version:
Active version
Passive version
Active fault monitoring
When an error state is detected, the two proportional solenoid
valves will be automatically deactivated, a red lamp will light-up
and drive the spool in neutral position (if it’s not seized up ).
The system will only react to failures of more than 500 ms ( in
other words there is delay of half a second before anything
happens ). An alarm signal is sent out through the connector, and
minus is opened.
This error state is memorized, and continues until the system is
being reset by switching o the supply voltage.
Shortly, when the active fault monitoring system is connected
and an error state is detected, the system ensures a fast and
operator free reaction, that will put the complete hydraulic circuit
into venting conditions, thus preventing uncontrollable machine
movements.
Passive fault monitoring
When an error state is detected, the two proportional solenoid
valves will not be deactivated, a red lamp will light-up, but still
control the main spool.
When a fault condition occurs, after a delay of 250 ms an alarm
signal is sent out through a devoted pin
This state is not memorized, and when the faulty state disappears,
the alarm signal will turn to passive again.
In order to prevent the electronic from going into an unde ned
state, any time the system is being triggered or reset, a general
check of power supply and the internal clock frequency is made.
The use of PEAC112 module both passive or active version, allows
the machines hydraulic system to be made with di erent level of
safety degree that for the choice of which it is essential to know
the exactly required functions.
When the PEAC112 module active version is connected with
the pump unloading system, the level of safety degree pro-
tection for the complete hydraulic system becomes very high,
operator free, and helps OEM to meet the PL ( Performance
Level ) required to be comply with the safety demands of Ma-
chinery Directive 2006/42/EC.
PDV74 - PEAC112 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal control 0 ÷ 10 V
HYDRAULIC POWER CONTROL
63
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PEAC112 is de ned by:
Inductive transducer with resolution < 12 µm
Integrated diagnosis and error memory
Fault monitoring transistor output for signal source
Higher spool control accuracy
EMC performace to
Low hysteresis
Quicker reaction time
Spool direction movement output
Integrated PWM/Pulse Width Modulation
Low electrical power
PDV74 - PEAC112 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal control 0 ÷ 10 V
PEAC112 Technical data
Rated supply voltage 10-30 Vdc
Max ripple 5%
Signal control 0-10 V
Range control signal 2,5 V to 7,5 V
Neutral spool position 5 V
Max threshold signal, A port 1 V
Max threshold signal, B port 1 V
Max current signal @ rated voltage 48 mA
Input capacitor 100 ηF
Signal control impedance 25 k
Power consumption 8,7 W
Heat insulation Class H (180°C)
Duty cycle ED 100%
Max current consumption 650 mA
Current consumption in neutral position 80 mA
Coil impedance @ 20°C 8,9 
Dither frequency 50-200 Hz
Recommended frequency 100 Hz
Enclouser degree (Electrical wiring excepted) IP 66 - IP 67 - IP 69K
Weight cast iron body 1,8 kg
Weight aluminium body 1,3 kg
Bootloader function, debugging parameters and set-up function available only
with Deutsch connector DT06-6S
Fault monitoring system
Max current on safety output (pin 5) 50 mA
Reaction time a fault 500 ms
Max current output signal for spool direction moviment 50 mA
Reaction time (constant voltage)
From neutral position to max spool travel 110 - 140 ms
From max spool travel to neutral 70 - 90 ms
Reaction time (neutral switch)
From neutral position to max spool travel 130 - 170 ms
From max spool travel to neutral 70 - 90 ms
HYDRAULIC POWER CONTROL
64
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
47
47,5
96.5
100,5
137,5
100,5
96.5
131.5
47
47,5
PDV74 - PEAC112 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal 0 ÷ 10 V - Electrical connectors
Deutsch connector DT06-6S
Enclousure degree IP 69K
PIN-assignment
2
3
6
5
1
4
1 Power supply
2 Input signal control
3 CAN-high
A port-spool
movement signal
4 CAN-low
B port-spool
movement signal
5 Fault monitoring signal
6 Ground
Connector version
Code numbers
Active version Passive version
Cast-iron body Aluminium body Cast-iron body Aluminium body
Deutsch DT06-6S PEAC0122000 PEAC1122000 PEAC0112000 PEAC1112000
DIN 43650 PEAC0122200 PEAC1122200 PEAC0112200 PEAC1112200
Hirschmann connector DIN 43650
Enclousure degree IP 65
PIN-assignment
1
2
3
4
1 Power supply
2 Input signal control
3 Fault monitoring signal
4 Ground
HYDRAULIC POWER CONTROL
65
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC112 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal control 0 ÷ 10 V
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
1
5
2
3
4
B
A
1
5
2
3
4
T
Ls P
Pg
Tg
Lp
Es
Ty
U+
SC
U-A
B
3B1A2
U+
SC
U-A
B
3B1A2
HYDRAULIC POWER CONTROL
66
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC112 Electro-hydraulic proportional actuation.
Closed loop spool control, high performance resolution
Input signal control 0 ÷ 10 V
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+
SC
U-A
B
3B1A2
U+
SC
U-A
B
3B1A2
HYDRAULIC POWER CONTROL
67
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC112 Electro-hydraulic proportional actuation.
Closed loop spool control, high performance resolution
Electrical block diagram for intelligent ring machine control
HMI / Joystick
Main power supply
Battery
Emergency stop or
Man present Switch
System
sensors
Hydraulic venting
MAIN CONTROLLER
Power Supply
System Logic
IN
LOGIC
OUT
Feedback
INPUT
Power Supply
Fault monitoring
PVE fault output
Electronic
circuit logic
MAIN CONTROL VALVE
Fault
detection
HYDRAULIC POWER CONTROL
68
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC112 Electro-hydraulic proportional actuation
Electrical wiring diagram with OMFB I/O controller
Input signal 0 ÷ 10 V
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
69
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC112 Electro-hydraulic proportional actuation
Electrical wiring diagram with OMFB I/O controller
Input signal 0 ÷ 10 V
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
70
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Pb
T
Pp
Pa
T
Pp
PID
μP
PEAC116 is a proportional high performance PDV spool actuation
with integrated electronics and inductive transducer ( LVDT ) that
operates safely and precisely the main spool movement according
to an electrical signal coming from a remote control.
The input signal by means of the PCB and the two proportional
pressure reducing valves, determines the level of the pilot pressu-
re which moves the main spool.
The spool position is detected in the LVDT transducer which gene-
rates an electric feed-back signal registered by the electronics.
The variation between the input signal and the feed-back signal,
actuates the solenoid valves accordingly, so that, the hydraulic
pilot pressure will drive the main spool in the right position.
All PEAC116 modules comes with integrated fault monitoring
system, available in two version:
Active version
Passive version
Active fault monitoring
When an error state is detected, the two proportional solenoid
valves will be automatically deactivated, a red lamp will light-up
and drive the spool in neutral position (if it’s not seized up ).
The system will only react to failures of more than 500 ms ( in
other words there is delay of half a second before anything
happens ). An alarm signal is sent out through the connector, and
minus is opened.
This error state is memorized, and continues until the system is
being reset by switching o the supply voltage.
Shortly, when the active fault monitoring system is connected
and an error state is detected, the system ensures a fast and
operator free reaction, that will put the complete hydraulic circuit
into venting conditions, thus preventing uncontrollable machine
movements.
Passive fault monitoring
When an error state is detected, the two proportional solenoid
valves will not be deactivated, a red lamp will light-up, but still
control the main spool.
When a fault condition occurs, after a delay of 250 ms an alarm
signal is sent out through a devoted pin
This state is not memorized, and when the faulty state disappears,
the alarm signal will turn to passive again.
In order to prevent the electronic from going into an unde ned
state, any time the system is being triggered or reset, a general
check of power supply and the internal clock frequency is made.
The use of PEAC116 module both passive or active version, allows
the machines hydraulic system to be made with di erent level of
safety degree that for the choice of which it is essential to know
the exactly required functions.
When the PEAC116 module active version is connected with
the pump unloading system, the level of safety degree pro-
tection for the complete hydraulic system becomes very high,
operator free, and helps OEM to meet the PL ( Performance
Level ) required to be comply with the safety demands of Ma-
chinery Directive 2006/42/EC.
PDV74 - PEAC116 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal 4 ÷ 20 mA
HYDRAULIC POWER CONTROL
71
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PEAC116 is de ned by:
Inductive transducer with resolution < 12 µm
Integrated diagnosis and error memory
Fault monitoring transistor output for signal source
Higher spool control accuracy
EMC performace according to Directive 2014/30/UE
Low hysteresis
Quicker reaction time
Spool direction movement output
Integrated PWM/Pulse Width Modulation
Low electrical power
Robust and reliable design
PDV74 - PEAC116 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal control 4 ÷ 20 mA
PEAC116 Technical data
Rated supply voltage 10 ÷ 30 Vdc
Max ripple 5%
Signal control 4 ÷ 20 mA
Range control signal 4 mA to 20 mA
Neutral spool position 12 mA
Max threshold signal, A port 1,5 mA
Max threshold signal, B port 1,5 mA
Max current signal @ rated voltage 48 mA
Input capacitor 100 ηF
Signal control impedance 220 
Power consumption 8,7 W
Heat insulation Class H (180°C)
Duty cycle ED 100%
Max current consumption 650 mA
Current consumption in neutral position 80 mA
Coil impedance @ 20°C 8,9 
Dither frequency 50 ÷ 200 Hz
Recommended frequency 100 Hz
Enclouser degree (Electrical wiring excepted) IP65 - IP66 - IP69K
Weight cast iron body 1,8 kg
Weight aluminium body 1,3 kg
Bootloader function, debugging parameters and set-up function available
with Deutsch connector DT06-6S, only
Fault monitoring system
Max current on safety output ( pin 5 ) 50 mA
Reaction time a fault 500 ms
Max current output signal for spool direction moviment 50 mA
Reaction time (constant voltage)
From neutral position to max spool travel 110 ÷ 140 ms
From max spool travel to neutral 70 ÷ 90 ms
Reaction time (neutral switch)
From neutral position to max spool travel 130 ÷ 170 ms
From max spool travel to neutral 70 ÷ 90 ms
HYDRAULIC POWER CONTROL
72
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
47
47,5
96.5
100,5
137,5
100,5
96.5
131.5
47
47,5
PDV74 - PEAC116 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal control 4 ÷ 20 mA - Electrical connectors
Deutsch connector DT06-6S
Enclousure degree IP 69K
PIN-assignment
2
3
6
5
1
4
1 Power supply
2 Input signal control
3 CAN-high
A port-spool
movement signal
4 CAN-low
B port-spool
movement signal
5 Fault monitoring signal
6 Ground
Hirschmann connector DIN 43650
Enclousure degree IP 65
PIN-assignment
1
2
3
4
1 Power supply
2 Input signal control
3 Fault monitoring signal
4 Ground
Connector version
Code numbers
Active version Passive version
Cast-iron body Aluminium body Cast-iron body Aluminium body
Deutsch DT06-6S PEAC0126000 PEAC1126000 PEAC0116000 PEAC1116000
DIN 43650 PEAC0126200 PEAC1126200 PEAC0116200 PEAC1116200
HYDRAULIC POWER CONTROL
73
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC116 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal 4 ÷ 20 mA
EMERGENCYE
Fuse
2A
T
P
B
A
U+
SC
U-A
B
Udc
-
+
3B1A2
U+
SC
U-A
B
3B1A2
1
5
2
3
4
B
A
1
5
2
3
4
T
Ls P
Pg
Tg
Lp
Es
Ty
HYDRAULIC POWER CONTROL
74
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC116 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Input signal control 4 ÷ 20 mA
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+
SC
U-A
B
3B1A2
U+
SC
U-A
B
3B1A2
HYDRAULIC POWER CONTROL
75
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC116 Electro-hydraulic proportional actuation
Closed loop spool control, high performance resolution
Electrical block diagram for intelligent ring machine control
HMI / Joystick
Main power supply
Battery
Emergency stop or
Man present Switch
System
sensors
Hydraulic venting
MAIN CONTROLLER
Power Supply
System Logic
IN
LOGIC
OUT
Feedback
INPUT
Power Supply
Fault monitoring
PVE fault output
Electronic
circuit logic
MAIN CONTROL VALVE
Fault
detection
HYDRAULIC POWER CONTROL
76
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC116 Electro-hydraulic proportional actuation.
Electrical wiring with OMFB I/O controller
Input signal 4 ÷ 20 mA
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
77
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC116 Electro-hydraulic proportional actuation
Electrical wiring diagram with OMFB I/O controller
Input signal 4 ÷ 20 mA
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
78
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC011 Electro-hydraulic proportional actuation
Open loop spool control, high performance resolution
Input signal control 0,5 Udc
Pb
T
Pp
Pa
T
Pp
PID
μP
PEAC011 is a proportional open loop spool actuation with
integrated electronics that operates the main spool movement
according to an electrical signal coming from a remote control.
The input signal by means of the PCB and the two proportional
pressure reducing valves, determines the level of the pilot pressu-
re which moves the main spool.
PEAC011 does not have neither the transducer spool position
control nor fault monitoring system, this means that any forces
which override the pilot pressure spool forces, may chenge the
spool position with no error signal, and the safety of the whole
system is left to the operator’s visual control, only.
PEAC011 is recommended where a simple proportional control
is required, and where hysteresis and reaction time are not so
critical.
HYDRAULIC POWER CONTROL
79
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC011 Electro-hydraulic proportional actuation
Open loop spool control, high performance resolution
Input signal control 0,5 Udc
PEAC011 Technical data
Rated supply voltage 10-30 Vdc
Max ripple 5%
Signal control 0,5 Udc
Range control signal 0,25 Udc to 0,75 Udc
Neutral spool position 0,5 Udc
Max threshold signal, A port 1 V
Max threshold signal, B port 1 V
Max current signal @ rated voltage 48 mA
Input capacitor 100 ηF
Signal control impedance 25 k
Power consumption 8,7 W
Heat insulation Class H (180°C)
Duty cycle ED 100%
Max current consumption 650 mA
Current consumption in neutral position 80 mA
Coil impedance @ 20°C 8,9 
Dither frequency 50-200 Hz
Recommended frequency 100 Hz
Enclouser degree (Electrical wiring excepted) IP 66 - IP 67 - IP 69K
Weight cast iron body 1,8 kg
Weight aluminium body 1,3 kg
Bootloader function, debugging parameters and set-up function available only
with Deutsch connector DT06-6S
Reaction time (constant voltage)
From neutral position to max spool travel 110 - 140 ms
From max spool travel to neutral 70 - 90 ms
Reaction time (neutral switch)
From neutral position to max spool travel 130 - 170 ms
From max spool travel to neutral 70 - 90 ms
PEAC011 is de ned by:
High spool control accuracy
EMC performace according to Directive 2014/30/UE
Quick reaction time
Integrated PWM/Pulse Width Modulation
Low electrical power
Robust and reliable design
HYDRAULIC POWER CONTROL
80
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Connector version
Code numbers
Active version Passive version
Cast-iron body Aluminium body Cast-iron body Aluminium body
Deutsch DT06-6S PEAC0021000 PEAC1021000 PEAC0011000 PEAC1011000
DIN 43650 PEAC0021200 PEAC1021200 PEAC0011200 PEAC1011200
PDV74 - PEAC011 Electro-hydraulic proportional actuation
Open loop spool control, high performance resolution
Input signal 0,5 Udc - Electrical connectors
Deutsch connector DT06-6S
Enclousure degree IP 69K
PIN-assignment
2
3
6
5
1
4
1 Power supply
2 Input signal control
3 CAN-high
4 CAN-low
5 Free
6 Ground
Hirschmann connector DIN 43650
Enclousure degree IP 65
PIN-assignment
1
2
3
4
1 Power supply
2 Input signal control
3 Free
4 Ground
47
47,5
96.5
100,5
137,5
100,5
96.5
131.5
47
47,5
HYDRAULIC POWER CONTROL
81
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC011 Electro-hydraulic proportional actuation
Open loop spool control, high performance resolution
Input signal control 0,5 Udc
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+
SC
U-A
B
3B1A2
U+
SC
U-A
B
3B1A2
HYDRAULIC POWER CONTROL
82
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC011 Electro-hydraulic proportional actuation
Open loop spool control, high performance resolution
Electrical block diagram for intelligent ring machine control
HMI / Joystick
Main power supply
Battery
Emergency stop or
Man present Switch
System
sensors
Hydraulic venting
MAIN CONTROLLER
Power Supply
System Logic
IN
LOGIC
OUT
Feedback
INPUT
Power Supply
Fault monitoring
PVE fault output
Electronic
circuit logic
MAIN CONTROL VALVE
Fault
detection
HYDRAULIC POWER CONTROL
83
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC011 Electro-hydraulic proportional actuation
Electrical wiring diagram with OMFB I/O controller
Input signal 0,5 Udc
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
84
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC011 Electro-hydraulic proportional actuation
Electrical wiring diagram with OMFB I/O controller
Input signal 0,5 Udc
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
85
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC012 Electro-hydraulic proportional actuation
Open loop spool control, high performance resolution
Input signal control 0 ÷ 10 V
Pb
T
Pp
Pa
T
Pp
PID
μP
PEAC012 is a proportional open loop spool actuation with
integrated electronics that operates the main spool movement
according to an electrical signal coming from a remote control.
The input signal by means of the PCB and the two proportional
pressure reducing valves, determines the level of the pilot pressu-
re which moves the main spool.
PEAC012 does not have neither the transducer spool position
control nor fault monitoring system, this means that any forces
which override the pilot pressure spool forces, may chenge the
spool position with no error signal, and the safety of the whole
system is left to the operator’s visual control, only.
PEAC012 is recommended where a simple proportional control
is required, and where hysteresis and reaction time are not so
critical.
HYDRAULIC POWER CONTROL
86
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC012 Electro-hydraulic proportional actuation
Open loop spool control, high performance resolution
Input signal control 0 ÷ 10 V
PEAC012 Technical data
Rated supply voltage 10-30 Vdc
Max ripple 5%
Signal control 0-10 V
Range control signal 2,5 V to 7,5 V
Neutral spool position 5 V
Max threshold signal, A port 1 V
Max threshold signal, B port 1 V
Max current signal @ rated voltage 48 mA
Input capacitor 100 ηF
Signal control impedance 25 k
Power consumption 8,7 W
Heat insulation Class H (180°C)
Duty cycle ED 100%
Max current consumption 650 mA
Current consumption in neutral position 80 mA
Coil impedance @ 20°C 8,9 
Dither frequency 50-200 Hz
Recommended frequency 100 Hz
Enclouser degree (Electrical wiring excepted) IP 66 - IP 67 - IP 69K
Weight cast iron body 1,8 kg
Weight aluminium body 1,3 kg
Bootloader function, debugging parameters and set-up function available only
with Deutsch connector DT06-6S
Reaction time (constant voltage)
From neutral position to max spool travel 110 - 140 ms
From max spool travel to neutral 70 - 90 ms
Reaction time (neutral switch)
From neutral position to max spool travel 130 - 170 ms
From max spool travel to neutral 70 - 90 ms
PEAC012 is de ned by:
High spool control accuracy
EMC performace according to Directive 2014/30/UE
Quick reaction time
Integrated PWM/Pulse Width Modulation
Low electrical power
Robust and reliable design
HYDRAULIC POWER CONTROL
87
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC012 Electro-hydraulic proportional actuation
Open loop spool control, high performance resolution
Input signal 0 ÷ 10 V - Electrical connectors
Connector version
Code numbers
Active version Passive version
Cast-iron body Aluminium body Cast-iron body Aluminium body
Deutsch DT06-6S PEAC0022000 PEAC1022000 PEAC0012000 PEAC1012000
DIN 43650 PEAC0022200 PEAC1022200 PEAC0012200 PEAC1012200
Deutsch connector DT06-6S
Enclousure degree IP 69K
PIN-assignment
2
3
6
5
1
4
1 Power supply
2 Input signal control
3 CAN-high
4 CAN-low
5 Free
6 Ground
Hirschmann connector DIN 43650
Enclousure degree IP 65
PIN-assignment
1
2
3
4
1 Power supply
2 Input signal control
3 Free
4 Ground
47
47,5
96.5
100,5
137,5
100,5
96.5
131.5
47
47,5
HYDRAULIC POWER CONTROL
88
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC012 Electro-hydraulic proportional actuation.
Open loop spool control, high performance resolution
Input signal control 0 ÷ 10 V
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+
SC
U-A
B
3B1A2
U+
SC
U-A
B
3B1A2
HYDRAULIC POWER CONTROL
89
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC012 Electro-hydraulic proportional actuation.
Open loop spool control, high performance resolution
Electrical block diagram for intelligent ring machine control
HMI / Joystick
Main power supply
Battery
Emergency stop or
Man present Switch
System
sensors
Hydraulic venting
MAIN CONTROLLER
Power Supply
System Logic
IN
LOGIC
OUT
Feedback
INPUT
Power Supply
Fault monitoring
PVE fault output
Electronic
circuit logic
MAIN CONTROL VALVE
Fault
detection
HYDRAULIC POWER CONTROL
90
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC012 Electro-hydraulic proportional actuation
Electrical wiring diagram with OMFB I/O controller
Input signal 0 ÷ 10 V
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
91
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC012 Electro-hydraulic proportional actuation
Electrical wiring diagram with OMFB I/O controller
Input signal 0 ÷ 10 V
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
92
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Pb
T
Pp
Pa
T
Pp
PID
μP
PEAC016 is a proportional open loop spool actuation with
integrated electronics that operates the main spool movement
according to an electrical signal coming from a remote control.
The input signal by means of the PCB and the two proportional
pressure reducing valves, determines the level of the pilot pressu-
re which moves the main spool.
PEAC016 does not have neither the transducer spool position
control nor fault monitoring system, this means that any forces
which override the pilot pressure spool forces, may chenge the
spool position with no error signal, and the safety of the whole
system is left to the operator’s visual control, only.
PEAC016 is recommended where a simple proportional control
is required, and where hysteresis and reaction time are not so
critical.
PDV74 - PEAC016 Electro-hydraulic proportional actuation
Open loop spool control
Input signal 4 ÷ 20 mA
HYDRAULIC POWER CONTROL
93
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PEAC016 is de ned by:
High spool control accuracy
EMC performace according to Directive 2014/30/UE
Quick reaction time
Integrated PWM/Pulse Width Modulation
Low electrical power
Robust and reliable design
PDV74 - PEAC016 Electro-hydraulic proportional actuation
Open loop spool control
Input signal 4 ÷ 20 mA
PEAC016 Technical data
Rated supply voltage 10-30 Vdc
Max ripple 5%
Signal control 4-20 mA
Range control signal 4 mA to 20 mA
Neutral spool position 12 mA
Max threshold signal, A port 1,5 mA
Max threshold signal, B port 1,5 mA
Input capacitor 100 ηF
Input impedance 220 
Power consumption 8,7 W
Heat insulation Class H (180°C)
Duty cycle ED 100%
Max current consumption 650 mA
Current consumption in neutral position 80 mA
Max current start spool travel 140 mA
Max current end spool travel 450 mA
Coil impedance @ 20°C 8,9 
Signal control impedance 50 K
Dither frequency 50-200 Hz
Recommended frequency 100 Hz
Enclouser degree (Electrical wiring excepted) IP65 - IP66 - IP69K
Bootloader function, debugging parameters and set-up function available
with Deutsch connector DT06-6S, only
Reaction time (constant voltage)
From neutral position to max spool travel 110 - 140 ms
From max spool travel to neutral 70 - 90 ms
Reaction time (neutral switch)
From neutral position to max spool travel 130 - 170 ms
From max spool travel to neutral 70 - 90 ms
HYDRAULIC POWER CONTROL
94
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC016 Electro-hydraulic proportional actuation.
Input signal control 4 ÷ 20 mA
Electrical connectors
Deutsch connector DT06-6S
Enclousure degree IP 69K
PIN-assignment
2
3
6
5
1
4
1 Power supply
2 Input signal control
3 CAN-high
4 CAN-low
5 Free
6 Ground
Hirschmann connector DIN 43650
Enclousure degree IP 65
PIN-assignment
1
2
3
4
1 Power supply
2 Input signal control
3 Free
4 Ground
Connector version
Code numbers
Active version Passive version
Cast-iron body Aluminium body Cast-iron body Aluminium body
Deutsch DT06-6S PEAC0026000 PEAC1026000 PEAC0016000 PEAC1016000
DIN 43650 PEAC0026200 PEAC1026200 PEAC0016200 PEAC1016200
47
47,5
96.5
100,5
137,5
100,5
96.5
131.5
47
47,5
HYDRAULIC POWER CONTROL
95
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC016 Electro-hydraulic proportional actuation.
Input signal control 4-20 mA
Electrical wiring
E
Fuse
2A
T
P
B
A
U+
SC
U-A
B
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
3B1A2
U+
SC
U-A
B
3B1A2
1
5
2
3
B
A
1
5
2
3
4
4
EMERGENCY
HYDRAULIC POWER CONTROL
96
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC016 Electro-hydraulic proportional actuation
Open loop spool control
Current input signal 4-20 mA
HMI / Joystick
Main power supply
Battery
Emergency stop or
Man present Switch
System
sensors
Hydraulic venting
MAIN CONTROLLER
Power Supply
System Logic
IN
LOGIC
OUT
Feedback
INPUT
Power Supply
Fault monitoring
PVE fault output
Electronic
circuit logic
MAIN CONTROL VALVE
Fault
detection
HYDRAULIC POWER CONTROL
97
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAC016 Electro-hydraulic proportional actuation.
Electrical wiring with OMFB I/O controller
Current input signal 4 ÷ 20 mA
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
98
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAC016 Electro-hydraulic proportional actuation.
Electrical wiring with OMFB I/O controller
Current input signal 4 ÷ 20 mA
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
99
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
Pb
T
Pp
Pa
T
Pp
PEAD1 is a proportional open loop spool actuation without
integrated electronics that operates the main spool movement
according to an electrical signal coming from a remote control.
The input signal by means of the two proportional pressure
reducing valves, determines the level of the pilot pressure which
moves the main spool.
PEAD1 does not have neither the transducer spool position con-
trol nor fault monitoring system, this means that any forces which
override the pilot pressure spool forces, may chenge the spool
position with no error signal, and the safety of the whole system is
left to the operators visual control, only.
PEAD1 is recommended where a simple proportional control is re-
quired, and where hysteresis and reaction time are not so critical.
PDV74 - PEAD1 Electro-hydraulic proportional actuation
Open loop spool control - Current input signal for PWM
or supply voltage for ON/OFF control
HYDRAULIC POWER CONTROL
100
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PEAD1 is de ned by:
High spool control accuracy
EMC performace according to Directive 2014/30/UE
Quick reaction time
Integrated PWM/Pulse Width Modulation
Low electrical power
Robust and reliable design
PDV74 - PEAD1 Electro-hydraulic proportional actuation
Open loop spool control - Current input signal for PWM
or supply voltage for ON/OFF control
PEAD1 Technical data
Supply voltage 12 Vdc 24 Vdc
Voltage range 10-16 V 20-30 V
Max ripple 5% 5%
Current consuption at rated voltage 750 mA @ 12 Vdc 400 mA @ 24 Vdc
Power consumption 9 W 9,6 W
R @ 20°C 8,9  35 
Start spool travel 220 mA 140 mA
End spool travel  ow control 650 mA 350 mA
Max spool  ow in pre- oating position 650 mA 350 mA
Spool  oating position 750 mA 400 mA
Heat insulation Class H (180°C)
Oil temperature (Recommended) 20 ÷ 60 °C
Oil temperature (Min) -30 °C
Oil temperature (Max) 80 °C
Ambient temperature -30 ÷ 60 °C
PWM frequency 50 ÷ 200 Hz
Best frequency 100 Hz
Duty cycle 100% ED
Plug connector 6 pins Deutsch or 4 pins DIN
Enclouser degree (Electrical wiring excepted) IP69K
Weight cast iron body 1, 8 kg
Weight Aluminium body 1,3 kg
Max current output signal for spool direction moviment 50 mA
Reaction time (constant voltage)
From neutral position to max spool travel 110 - 140 ms
From max spool travel to neutral 70 - 90 ms
Reaction time (neutral switch)
From neutral position to max spool travel 130 - 170 ms
From max spool travel to neutral 70 - 90 ms
HYDRAULIC POWER CONTROL
101
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAD1 Electro-hydraulic proportional actuation
Open loop spool control - Current input signal for PWM
or supply voltage for ON/OFF control - Electrical connectors
Deutsch connector DT06-6S
Enclousure degree IP 69K
PIN-assignment
2
3
6
5
1
4
1A port +
2 Free
3A port -
4B port +
5 Free
6B port -
Hirschmann connector DIN 43650
Enclousure degree IP 65
PIN-assignment
1
2
3
4
1A port +
2B port +
3 Free
4 Ground
Connector version
Code numbers
12 V 24 V
Cast-iron body Aluminium body Cast-iron body Aluminium body
Deutsch DT06-6S PEAD0100000 PEAD1100000 PEAD0200000 PEAD1200000
DIN 43650 PEAD0120000 PEAD1120000 PEAD0220000 PEAD1220000
47
47,5
96.5
100,5
137,5
100,5
96.5
131.5
47
47,5
Coil B
Coil A
PWM A
GND
PWM B
1
HYDRAULIC POWER CONTROL
102
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAD1 Electro-hydraulic proportional actuation.
Electrical wiring with OMFB I/O controller - Current input signal
for PWM or supply voltage for ON/OFF control
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
6
6
HYDRAULIC POWER CONTROL
103
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAD1 Electro-hydraulic proportional actuation.
Electrical wiring with OMFB I/O controller - Current input signal
for PWM or supply voltage for ON/OFF control
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
6
6
HYDRAULIC POWER CONTROL
104
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAD1 Electro-hydraulic proportional actuation.
Electrical wiring with OMFB I/O controller - Current input signal
for PWM or supply voltage for ON/OFF control
Udc
-
+
Out + B X
Out + A X
14
314
6
3
5
1
By
Com
U+
S
X
U-
Tapx
AY
911
12
10
8
Tapy
U+
S
Y
U-
7
15
Bx
Com
Ax
Out + B Y
Out + A Y
S1
2
3
4
1
8
S4
Com
SW
9
Top
5
S5
9
S6
11
12
S2
S3
Tr
Tr
Pump
unloading
Person present
Switch
PB 1
PB 2
PB 3
PB 4
PB 5
PB 6
Top Switch
I/O controller
BFMO
HYDRAULIC POWER CONTROL
EMERGENCYE
Fuse
2A
T
P
B
A
T
Ls P
Pg
Tg
Lp
Es
Ty
1
5
2
3
B
A
1
5
2
3
4
4
6
6
HYDRAULIC POWER CONTROL
105
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
Pb
T
Pp
Pa
T
Pp
PEAP1 is a proportional open loop spool actuation without
integrated electronics that operates the main spool movement
according to an electrical signal coming from a remote control.
The input signal by means of the two proportional pressure
reducing valves, determines the level of the pilot pressure which
moves the main spool.
PEAP1 does not have neither the transducer spool position con-
trol nor fault monitoring system, this means that any forces which
override the pilot pressure spool forces, may chenge the spool
position with no error signal, and the safety of the whole system is
left to the operators visual control, only.
PEAP1 is recommended where a simple proportional control is re-
quired, and where hysteresis and reaction time are not so critical.
PDV74 - PEAP1 Electro-hydraulic proportional actuation
Open loop spool control - Current input signal for PWM
or supply voltage for ON/OFF control
HYDRAULIC POWER CONTROL
106
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PEAP1 is de ned by:
High spool control accuracy
EMC performace according to Directive 2014/30/UE
Quick reaction time
Integrated PWM/Pulse Width Modulation
Low electrical power
Robust and reliable design
PDV74 - PEAP1 Electro-hydraulic proportional actuation
Open loop spool control - Current input signal for PWM
or supply voltage for ON/OFF control
PEAP1 Technical data
Supply voltage 12 Vdc 24 Vdc
Voltage range 10-16 V 20-30 V
Max ripple 5% 5%
Current consuption at rated voltage 1330 mA @ 12 Vdc 630 mA @ 24 Vdc
Power consumption 23 W 21 W
R @ 20°C 6,3  27 
Start spool travel 220 mA 140 mA
End spool travel  ow control 1330 mA 550 mA
Max spool  ow in pre- oating position 1330 mA 630 mA
Spool  oating position 750 mA 400 mA
Heat insulation Class H (180°C)
Oil temperature (Recommended) -20 ÷ 60 °C
Oil temperature (Min) -30 °C
Oil temperature (Max) 80 °C
Ambient temperature -30 ÷ 60 °C
PWM frequency 50 ÷ 200 Hz
Best frequency 100 Hz
Duty cycle 100% ED
Plug connector Amp Junior Power Timer 4 pins
Enclouser degree (Electrical wiring excepted) IP69K
Max current output signal for spool direction moviment 50 mA
Reaction time (constant voltage)
From neutral position to max spool travel 110 - 140 ms
From max spool travel to neutral 70 - 90 ms
Reaction time (neutral switch)
From neutral position to max spool travel 130 - 170 ms
From max spool travel to neutral 70 - 90 ms
HYDRAULIC POWER CONTROL
107
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PWM A
GND
PWM B
Coil BCoil A
1
PDV74 - PEAP1 Electro-hydraulic proportional actuation
Input signal control PWM - Current input signal for PWM
or supply voltage for ON/OFF control - Electrical connector
Amp Junior Power Timer 4 pin connector
Enclousure degree IP 65
PIN-assignment
1
2
3
4
1A port +
2A port -
3B port -
4B port +
Connector version
Code numbers
12 V 24 V
Cast-iron body Aluminium body Cast-iron body Aluminium body
AMP Junior timer 4 Pin PEAP0312000 PEAP1312000 PEAP0412000 PEAP1412000
5757
101.5
176
47
HYDRAULIC POWER CONTROL
108
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAP1 Electro-hydraulic proportional actuation
Electrical wiring with OMFB I/O controller - Current input signal
for PWM or supply voltage for ON/OFF control
I/O controller
EMERGENCYE
Fuse
2A
T
P
B
A
Udc
-
+
T
Ls
P
Pg
Tg
Lp
Es
Ty
B
A
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAULIC POWER CONTROL
HYDRAULIC POWER CONTROL
109
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 - PEAP1 Electro-hydraulic proportional actuation
Electrical wiring with OMFB I/O controller - Current input signal
for PWM or supply voltage for ON/OFF control
I/O controller
EMERGENCYE
Fuse
2A
Udc
-
+
U+SCU-A
B
3B
1
A2
U+SCU-A
B
3B
1
A2
BFMO
HYDRAU LIC P OWER CO NTROL
T
P
B
A
T
Ls
P
Pg
Tg
Lp
Es
Ty
B
A
HYDRAULIC POWER CONTROL
110
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 - PEAP1 Electro-hydraulic proportional actuation
Electrical wiring with OMFB I/O controller - Current input signal
for PWM or supply voltage for ON/OFF control
Udc
-
+
Out + B X
Out + A X
14
314
6
3
5
1
By
Com
U+
S
X
U-
Tapx
AY
911
12
10
8
Tapy
U+
S
Y
U-
7
15
Bx
Com
Ax
Out + B Y
Out + A Y
S1
2
3
4
1
8
S4
Com
SW
9
Top
5
S5
9
S6
11
12
S2
S3
Tr
Tr
Pump
unloading
Person present
Switch
PB 1
PB 2
PB 3
PB 4
PB 5
PB 6
Top Switch
I/O controller
BFMO
HYDRAULIC POWER CONTROL
T
P
B
A
T
Ls P
Pg
Tg
Lp
Es
Ty
B
A
EMERGENCYE
Fuse
2A
HYDRAULIC POWER CONTROL
111
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
HYDRAULIC POWER CONTROL
112
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
293 max
221
79 max
114 100
60
8,4
48
L1
L2
A
B
D
C
J
R
Q
SH
G
L T
I
V
U
W
M
F
N
158
P
K
O
E
PDV74 Proportional valve
Overall dimensions drawing with standard inlet section
Right assembly version
PDW
123456789101112
L1
mm 180 228 276 324 372 420 468 516 564 612 660 708
in 7,09 8,98 10,87 12,76 14,65 16,54 18,43 20,31 22,20 24,09 25,98 27,87
L2
mm 200 248 296 344 392 440 488 536 584 632 680 728
in 7,87 9,76 11,65 13,54 15,43 17,32 19,21 21,10 22,99 24,88 26,77 28,66
HYDRAULIC POWER CONTROL
113
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
= Pump side port - 3/4” BSPP - 17 mm deep [1 ⁄in 12 UN-2B - 0,67 in deep]
= T port - 3/4” BSPP - 17 mm deep [1 ⁄in 12 UN - 2B - 0,67 in deep]
= Main pressure relief valve
= Main pressure reducing valve
= Pump pressure gauge connection - 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= LS connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= External pilot pressure supply connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= External feeding main pressure reducing valve 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= Tank pressure gauge connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= Electrical LS/pump unloading function
= Pump unloading drain port, 1/4” BSPP - 12 mm deep [⁄ in-20 UNF - 2B - 0,47 in deep]
= Pump unloading mechanical override
= A-B port mechanical  ow adjustment
= LSA
= LSB remote pilot pressure connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF - 2B - 0,47 in deep]
= LS
= Port A
= Port B
= LsB
= LsA
= Shock/suction valve B port
= Shock/suction valve A port
= External drain connection electric actuations - 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
}
}
1/2” BSPP - 17 mm deep [⁄ in-14 UNF-2B - 0,67 in deep]
pilot pressure relief valve
}
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
L
L
M
M
N
N
O
O
P
P
Q
Q
R
R
S
S
T
T
U
U
V
V
W
W
PDV74 Proportional valve
Overall dimensions drawing with standard inlet section
Right assembly version
HYDRAULIC POWER CONTROL
114
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 with open centre inlet section ( xed displacement pump),
pump unloading system, pilot oil supply for electro-hydraulic
spool actuations
PDV74 Proportional valve
Hydraulic diagram
HYDRAULIC POWER CONTROL
115
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional valve
Hydraulic diagram
PDV74 with closed centre inlet section (variable displacement
pump), pilot oil supply for electro-hydraulic
spool actuations
HYDRAULIC POWER CONTROL
116
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional Valve
PDV ____ supplied by a  xed displacement pump
Tg
Lp
T
Ls
P
A
B
Ls
LsA
LsB
A
B
Ls
LsA
LsB
A
B
Ls
LsA
LsB
A
B
Ls
LsA
LsB
Tg
Lp
Pg
ES
T
Ls
P
Pg
ES
Closed center
Inlet secƟ on
Open center
Inlet secƟ on
HYDRAULIC POWER CONTROL
117
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional Valve
PDV - ___supplied by Ls pump
A
B
Ls
LsA
LsB
A
B
Ls
LsA
LsB
A
B
Ls
LsA
LsB
A
B
Ls
LsA
LsB
Tg
Lp
Pg
ES
T
Ls
P
TLsP
Tg
Lp
Pg
ES
Closed center
Inlet secƟ on
Closed center
Inlet secƟ on
HYDRAULIC POWER CONTROL
118
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDI
PDW
PDE
PSB
PDV74 Proportional Valve
PSB Stay bolt kit - Standard con guration
PDW Code numbers Tightening torque
1 PSB70011000
25 ± 2 Nm
220 ±18 lb*in
2 PSB70021000
3 PSB70031000
4 PSB70041000
5 PSB70051000
6 PSB70061000
7 PSB70071000
8 PSB70081000
9 PSB70091000
10 PSB70101000
HYDRAULIC POWER CONTROL
119
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
HYDRAULIC POWER CONTROL
120
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
79 max
114 100
293
158
221
48
60
8,4
L1
L2
40
L3
25
2 x
M8-6H
A
B
D
C
J
R
Q
SH
G
L T
I
U
V
W
M
F
E
K
N
P
O
R
Q
A
B
16
PDW 23456789101112
L1
mm 331 379 427 475 523 571 619 667 715 763 811
in 13,03 14,92 16,81 18,70 20,59 22,48 24,37 26,26 28,15 30,04 31,93
L2
mm 351 399 447 495 543 591 639 687 735 783 831
in 13,82 15,71 17,60 19,49 21,38 23,27 25,16 27,05 28,94 30,83 32,72
PDV74 Proportional valve
Overall dimensions drawing with double inlet section
and MID end
HYDRAULIC POWER CONTROL
121
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
= Pump side port - 3/4” BSPP - 17 mm deep [1 ⁄in 12 UN-2B - 0,67 in deep]
= T port - 3/4” BSPP - 17 mm deep [1 ⁄in 12 UN - 2B - 0,67 in deep]
= Main pressure relief valve
= Main pressure reducing valve
= Pump pressure gauge connection - 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= LS connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= External pilot pressure supply connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= External feeding main pressure reducing valve 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= Tank pressure gauge connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= Electrical LS/pump unloading function
= Pump unloading drain port, 1/4” BSPP - 12 mm deep [⁄ in-20 UNF - 2B - 0,47 in deep]
= Pump unloading mechanical override
= A-B port mechanical  ow adjustment
= LSA
= LSB remote pilot pressure connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF - 2B - 0,47 in deep]
= LS
= Port A
= Port B
= LsB
= LsA
= Shock/suction valve B port
= Shock/suction valve A port
= External drain connection electric actuations - 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
}
}
1/2” BSPP - 17 mm deep [⁄ in-14 UNF-2B - 0,67 in deep]
pilot pressure relief valve
}
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
L
L
M
M
N
N
O
O
P
P
Q
Q
R
R
S
S
T
T
U
U
V
V
W
W
PDV74 Proportional valve
Overall dimensions drawing with double inlet section
and MID end
HYDRAULIC POWER CONTROL
122
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional valve
Hydraulic diagram
PDV74 with double closed centre inlet section (variable di-
splacement pump), pilot oil supply for electro-hydraulic
spool actuations
HYDRAULIC POWER CONTROL
123
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional valve
Hydraulic diagram
HYDRAULIC POWER CONTROL
124
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDI
PDW
PDEM
PSB
PDI
PDW
PSB
PDW Code numbers Tightening torque
1
PSB72011000
25 ± 2 Nm
220 ±18 lb*in
2
PSB72021000
3
PSB72031000
4
PSB72041000
5
PSB72051000
6
PSB72061000
PDV74 Proportional Valve
PSB Stay bolt kit - Double inlet sections and
MID end section con guration
HYDRAULIC POWER CONTROL
125
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
HYDRAULIC POWER CONTROL
126
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
221
100 114
79 max
293 max
158
48
60
8,4
L1
L2
65
28
L3
2 x
6,8 14
M8 - 6H
12
A
B
J
Q
R
S T
W
U
V
M
N
P
O
Q
R
PDV74 Proportional valve
Overall dimensions drawing with closed centre MID inlet section
HYDRAULIC POWER CONTROL
127
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
= Pump side port - 3/4” BSPP - 17 mm deep [1 ⁄in 12 UN-2B - 0,67 in deep]
= T port - 3/4” BSPP - 17 mm deep [1 ⁄in 12 UN - 2B - 0,67 in deep]
= Main pressure relief valve
= Main pressure reducing valve
= Pump pressure gauge connection - 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= LS connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= External pilot pressure supply connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= External feeding main pressure reducing valve 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= Tank pressure gauge connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
= Electrical LS/pump unloading function
= Pump unloading drain port, 1/4” BSPP - 12 mm deep [⁄ in-20 UNF - 2B - 0,47 in deep]
= Pump unloading mechanical override
= A-B port mechanical  ow adjustment
= LSA
= LSB remote pilot pressure connection 1/4” BSPP - 12 mm deep [⁄ in-20 UNF - 2B - 0,47 in deep]
= LS
= Port A
= Port B
= LsB
= LsA
= Shock/suction valve B port
= Shock/suction valve A port
= External drain connection electric actuations - 1/4” BSPP - 12 mm deep [⁄ in-20 UNF-2B - 0,47 in deep]
}
}
1/2” BSPP - 17 mm deep [⁄ in-14 UNF-2B - 0,67 in deep]
pilot pressure relief valve
}
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
L
L
M
M
N
N
O
O
P
P
Q
Q
R
R
S
S
T
T
U
U
V
V
W
W
PDV74 Proportional valve
Overall dimensions drawing with closed centre MID inlet section
HYDRAULIC POWER CONTROL
128
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
PDV74 Proportional valve
Hydraulic diagram
PDV74 with MID-inlet closed centre section
(variable displacement pump), pilot oil supply for
electro-hydraulic spool actuations
HYDRAULIC POWER CONTROL
129
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDIM
PDW
PDE
PSB
PDW
PSB
PDE
PDW Code numbers Tightening torque
1
PSB71011000
25 ± 2 Nm
220 ±18 lb*in
2
PSB71021000
3
PSB71031000
4
PSB71041000
5
PSB71051000
6
PSB71061000
PDV74 Proportional Valve
PSB Stay bolt kit - MID inlet section con guration
HYDRAULIC POWER CONTROL
130
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
P
T
T
B
P
T
T
ABA
A
B
AA
A
B
B
B
P
T
PUSH
PULL
PDV74 Proportional valve
Right side version
HYDRAULIC POWER CONTROL
131
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
P
T
T
B
P
T
T
A BA
A
B
A
A
A
B
B
B
P
T
PUSH
PULL
PDV74 Proportional valve
Left side version
HYDRAULIC POWER CONTROL
132
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
0
1-10
11
PWS
PWA
PWP
PWR
19
12
13
14
15
16
17
18
20
21
22
PDM
PIU
PDS
PDR
PDL
PSB
PDI
PDW
PDE
PEACX01
PEAC1
PEAD1
PDD
PDF
PDC
PEAP1
PEI
PED
PDH
PIZ
PIY
PLS0A
PLS0P
PDL05
PIP
PDV74 Proportional valve
Con guration with standard inlet section - Right side assembly
Product selection chart
This speci cation sheet, gives an overview of any modules with which the PDV74 is being assembled. Each module
has its own  eld. The purpose of this chart is to provide a quick access to the modules choice, whose characteristics
must always be checked on the catalog related data.
PDZ
PEAC0
PEAC018
PEAC118
PEACX11
PEADX1
23
20
PLS0A
PLS0P
24
PRV7A
PRV7P
21
HYDRAULIC POWER CONTROL
133
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional valve,
Product selection chart, with standard inlet section
Reference
eld
Description
Code numbers
see pag
0
Inlet sections
Open centre
PDI
18 - 19
Closed centre 21 - 22
1-10
Working sections
with pressure compensator
PDW
25 - 26
without pressure compensator 27 - 28
11
End sections PDE 29 - 30
12
Stay bolt set PSB 118
13
Pilot oil supply cartridge
Internal PIZ 45
External PIY 45
14
Solenoid Ls unloading PIU 23 - 24
Plug for LS unloading cavity PIP 23
15
Mechanical actuation PDM 42
16
Spool PDS From 33 to 41
17
Spool centered set PDR From 35 to 41
18
Unloading module PDL From 49 to 53
Cover plate PDL05
19
Shock and suction valve
not adjustable PWS 46 - 47
adjustable PWA 46 - 47
Plug for shock and suction valve cavity PWP 48
Suction valve PWR 48
20
Pilot pressure LSA/B relief valve PLS0A 43
Set plug LSA/B cavity PLS0P 43
21
Proportional electro-
hydraulic actuations
Open loop spool control current signal for
PWM and ON-OFF control
PEAD1 From 99 to 104
Open loop spool control high resolution PEAC0 From 78 to 98
Closed loop spool
control high performance resolution
PEAC1 From 54 to 77
Open loop spool
control high resolution CAN-Bus
PEAC018
Closed loop spool control high performance
resolution CAN-Bus
PEAC118
Open loop spool control high resolution ATEX PEACX01
Closed loop spool control high performance
resolution ATEX version
PEACX11
Open loop spool control current signal for
PWM and ON-OFF control ATEX version
PEADX1
Open loop spool control current input signal
for PWM and ON-OFF control - AMP JPT 4 pin
PEAP1 From 105 to 110
Rear cover for
Hydraulic control PDH 43
Detent PDD 44
Friction detent PDF 42
Mechanical actuation PDC 43
22
End sections
External drain line cartridge PED 45
Internal plug PEI 45
23
Dual function control body PDZ 31 - 32
24
Pump pressure relief valve (for closed centre only) PRV0A
Plug for relief valve cavity (for closed centre only) PRV0P
HYDRAULIC POWER CONTROL
134
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
0A
1A-6A
11
PWS
PWA
PWP
PWR
19
12
13
14
15
16
17
18
20
PDM
PIU
PDS
PDR
PDL
PSB
PDI
PDW
PDEM
PIZ
PIY
PLS0A
PLS0P
PDL05
PIP
1-6
0
12A
PDW
PDI
PSB
PDV74 Proportional valve, product selection chart
Con guration with double inlet sections and MID end section
20
PLS0A
PLS0P
24
PRV7A
PRV7P
21
PEACX01
PEAC1
PEAD1
PDD
PDF
PDC
PEAP1
PDH
PDZ
PEAC0
PEAC018
PEAC118
PEACX11
PEADX1
23
21
HYDRAULIC POWER CONTROL
135
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional valve,
Product selection chart, with double inlet sections and MID end section
Reference
eld
Description
Code numbers
see pag
0
0A
Inlet sections
Open centre
PDI
18 - 19
Closed centre 21 - 22
1-6
1A-6A
Working sections
with pressure compensator
PDW
25 - 26
without pressure compensator 27 - 28
11
End sections PDEM 30
12
12A
Stay bolt set PSB 124
13
Pilot oil supply cartridge
Internal PIZ 45
External PIY 45
14
Solenoid Ls unloading PIU 23 - 24
Plug for LS unloading cavity PIP 23
15
Mechanical actuation PDM 42
16
Spool PDS From 33 to 41
17
Spool centered set PDR From 35 to 41
18
Unloading module PDL From 49 to 53
Cover plate PDL05
19
Shock and suction valve
not adjustable PWS 46 - 47
adjustable PWA 46 - 47
Plug for shock and suction valve cavity PWP 48
Suction valve PWR 48
20
Pilot pressure LSA/B relief valve PLS0A 43
Set plug LSA/B cavity PLS0P 43
21
Proportional electro-
hydraulic actuations
Open loop spool control current signal for
PWM and ON-OFF control
PEAD1 From 99 to 104
Open loop spool control high resolution PEAC0 From 78 to 98
Closed loop spool
control high performance resolution
PEAC1 From 54 to 77
Open loop spool
control high resolution CAN-Bus
PEAC018
Closed loop spool control high performance
resolution CAN-Bus
PEAC118
Open loop spool control high resolution ATEX PEACX01
Closed loop spool control high performance
resolution ATEX version
PEACX11
Open loop spool control current signal for
PWM and ON-OFF control ATEX version
PEADX1
Open loop spool control current input signal
for PWM and ON-OFF control - AMP JPT 4 pin
PEAP1 From 105 to 110
Rear cover for
Hydraulic control PDH 43
Detent PDD 44
Friction detent PDF 42
Mechanical actuation PDC 43
22
End sections
External drain line cartridge PED 45
Internal plug PEI 45
23
Dual function control body PDZ 31 - 32
24
Pump Pressure relief valve (for closed centre only) PRV0A
Plug for relief valve cavity (for closed centre only) PRV0P
HYDRAULIC POWER CONTROL
136
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
12A
PSB
PDV74 Proportional valve, product selection chart
Con guration with MID inlet section
11A
1A-6A
11
PWS
PWA
PWP
PWR
19
12
14
15
16
17
18
20
22
PDM
PIU
PDS
PDR
PDL
PSB
PDE
PDW
PDE
PEI
PED
PLS0A
PLS0P
PDL05
PIP
PDIM
0
1-6
PDW
14
PIU
PIP
21
PEACX01
PEAC1
PEAD1
PDD
PDF
PDC
PEAP1
PDH
PDZ
PEAC0
PEAC018
PEAC118
PEACX11
PEADX1
23
21
HYDRAULIC POWER CONTROL
137
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
PDV74 Proportional valve,
Product selection chart, with MID inlet section
Reference
eld
Description
Code numbers
see pag
0
Inlet sections Closed centre PDIM 22
1-6
1A-6A
Working sections
with pressure compensator
PDW
25 - 26
without pressure compensator 27 - 28
11
11A
End sections PDE 29 - 30
12
12A
Stay bolt set PSB 129
14
Solenoid Ls unloading PIU 23 - 24
Plug for LS unloading cavity PIP 23
15
Mechanical actuation PDM 42
16
Spool PDS From 33 to 41
17
Spool centered set PDR From 35 to 41
18
Unloading module PDL From 49 to 53
Cover plate PDL05
19
Shock and suction valve
not adjustable PWS 46 - 47
adjustable PWA 46 - 47
Plug for shock and suction valve cavity PWP 48
Suction valve PWR 48
20
Pilot pressure LSA/B relief valve PLS0A 43
Set plug LSA/B cavity PLS0P 43
21
Proportional electro-
hydraulic actuations
Open loop spool control current signal for
PWM and ON-OFF control
PEAD1 From 99 to 104
Open loop spool control high resolution PEAC0 From 78 to 98
Closed loop spool
control high performance resolution
PEAC1 From 54 to 77
Open loop spool
control high resolution CAN-Bus
PEAC018
Closed loop spool control high performance
resolution CAN-Bus
PEAC118
Open loop spool control high resolution ATEX PEACX01
Closed loop spool control high performance
resolution ATEX version
PEACX11
Open loop spool control current signal for
PWM and ON-OFF control ATEX version
PEADX1
Open loop spool control current input signal
for PWM and ON-OFF control - AMP JPT 4 pin
PEAP1 From 105 to 110
Rear cover for
Hydraulic control PDH 43
Detent PDD 44
Friction detent PDF 42
Mechanical actuation PDC 43
22
End sections
External drain line cartridge PED 45
Internal plug PEI 45
23
Dual function control body PDZ 31 - 32
24
Pump Pressure relief valve PRV0A
Plug for relief valve cavity PRV0P
HYDRAULIC POWER CONTROL
138
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Code:
PDV74
Date: __/__/____
Review index: -
Review date: -
I
PDV 74
V
10
IX
Rated voltage [V]:
II
BSPP
XVI
CerƟĮcaƟons:
III
standard
VII
Right version
XI
IV
Open Center
XIIVIII
Pump Ňow [l/min]:
0
bar
13
41
ActuĂƟon side Handle side
121
rabrab
1516
17
2020
9119
18
21
rabrab
17
20
19
rabrab
rabrab
rabrab
rabrab
rabrab
rabrab
rabrab
rabrab
PDV ComposiƟŽnform rev. 01ඵ 06/07/2020
O.M.F.B. S.p.A. - Hydraulic Components - 25050 Provaglio d’Iseo (BS) - Via Cave, 7/9
7
8
9
10
2
3
4
5
6
1
Pump type:
None
B Port
2
nd
pump type:
Valve type:
Type of threads:
Type of inlet:
12
A Port
Customer:
Customer ref:
OMFB sales ref:
Working secƟons Up:
Working secƟons Down:
Inlet secƟon side:
Issued by:
Notes
Notes
2
19
20
16
15
3
21
17
20
19
19
20
16
15
21
17
20
19
19
20
16
15
21
17
20
19
19
20
16
15
21
17
20
19
19
20
16
15
21
17
20
19
19
20
16
15
21
17
20
19
19
20
16
15
21
17
20
19
19
20
16
15
21
17
20
19
19
20
16
15
4
5
6
7
8
9
10
11
12
22
0
11
18
18
18
18
18
18
18
18
18
20
24
23
23
23
23
23
23
23
23
23
PDV74 Proportional valve
Composition form for standard inlet section
HYDRAULIC POWER CONTROL
139
997PDV00074 // 25/08/2022 99740000PDV AC 11/06/2021
Code:
Date: __/__/____
Review index: -
Review date: -
1
PDV 74
5
6
9
Rated voltage [V]:
2
BSPP
6
6
10
CerƟĮcaƟŽŶs:
3
mid_end
7
Right version
11
4
Open Center
218
Pump Ňow [l/min]:
0A
bar
13
14
Actuators side Handle side
rabrab
rabrab
rabrab
rabrab
rabrab
rabrab
rabrab
rabrab
rabrab
rabrab
rabrab
121
rabrab
1516
17 2020
1919
18
0
bar
13
14
Actuators side Handle side
PDV ComposiƟon form rev. 01 06/07/2020
O.M.F.B. S.p.A. - Hydraulic Components - 25050 Provaglio d’Iseo (BS) - Via Cave, 7/9
B AtroP Port
A BtroP Port
5
4
3
2
1
6
2A
3A
4A
5A
6A
1A
Pump type:
None
2
nd
pump type:
Notes:
Valve type:
Type of threads:
Type of inlet:
12
Customer:
Customer ref:
OMFB sales ref:
Working secƟŽŶs Up:
Working secƟŽŶs Down:
Inlet secƟŽn side:
Issued by:
Notes:
PDV74
221 1516
17 2020
1919
18
321 1516
17 2020
1919
18
421 1516
17 2020
1919
18
521 1516
17 2020
1919
18
621 1516
17 2020
1919
18
6A21 1516
17 2020
1919
18
5A21 1516
17 2020
1919
18
4A21 1516
17 2020
1919
18
3A21 1516
17 2020
1919
18
2A21 1516
17 2020
1919
18
1A
21 1516
17 2020
1919
18
11
12
12A
PDV74 Proportional valve
Composition form with double inlet section and MID End section
HYDRAULIC POWER CONTROL
140
99740000PDV AC 11/06/2021
997PDV00074 // 25/08/2022
Code:
PDV74
Date: __/__/____
Review index: -
Review date: -
1
PDV 74
5
6
9
Rated voltage [V]:
2
BSPP
6
6
10
CerƟĮcaƟŽŶs:
3
mid_inlet
7
Right version
11
4
Open Center
218
Pump Ňow [l/min]:
Actuators side Handle side
6A21
rabrab
1516
17 2020
1919
18
rabrab
rabrab
rabrab
rabrab
rabrab
bar
rabrab
rabrab
rabrab
rabrab
rabrab
rabrab
Actuators side Handle side
PDV ComposiƟon form rev. 01 06/07/2020
O.M.F.B. S.p.A. - Hydraulic Components - 25050 Provaglio d’Iseo (BS) - Via Cave, 7/9
B AtroP Port
2
3
4
5
6
1
5A
4A
3A
2A
1A
6A
Pump type:
None
A BtroP Port
2
nd
pump type:
Valve type:
Type of threads:
Type of inlet:
12
Customer:
Customer ref:
OMFB sales ref:
Working secƟŽŶs Up:
Working secƟŽŶs Down:
Inlet secƟŽn side:
Issued by:
Notes: Notes:
5A21 1516
17 2020
1919
18
4A21 1516
17 2020
1919
18
3A21 1516
17 2020
1919
18
2A21 1516
17 2020
1919
18
1A21 1516
17 2020
1919
18
121 1516
17 2020
1919
18
221 1516
17 2020
1919
18
321 1516
17 2020
1919
18
421 1516
17 2020
1919
18
521 1516
17 2020
1919
18
6
21 1516
17 2020
1919
18
0
14
11
12
22
11A
12A
22
PDV74 Proportional valve
Composition form with MID inlet section